Visage™ Digital Installation Guide  4

Special notes for combination boiler 

systems

The appliance must have a minimum domestic hot 

water rating of 24kW and be of the type fitted 

with a fully modulating gas valve. If in any doubt, 

please contact the appliance manufacturer before 

installation commences.

DUE TO PERFORMANCE CHARACTERISTICS 

OF COMBINATION BOILERS, SEASONAL 

INLET TEMPERATURE CHANGE WILL AFFECT 

THE QUARTZ SMART VALVE™ OUTLET FLOW 

RATE RESULTING IN VARYING SHOWER 

FLOW RATE AND FLOW CONTROL RANGE. 

INLET TEMPERATURE CHANGE MAY 

ALSO CAUSE THE TEMPERATURE DISPLAY 

TO FLASH; THIS IS NOT NECESSARILY 

CHANGING THE OUTLET TEMPERATURE. 

DUE TO THE PERFORMANCE 

CHARACTERISTICS OF COMBINATION 

BOILERS, OPERATION OF THE BOOST 

BUTTON OR INCREASING THE FLOW RATE 

SETTING ON THE SHOWER CONTROLLER 

MAY NOT OFFER SIGNIFICANT CHANGE IN 

OUTPUT FLOW RATE. 

Special notes for separately pumped 

gravity systems and universal/negative 

head pumps (for divert systems)

We recommend a 

MINIMUM pump rating 

of 1.5 bar. For optimum performance a 2.5 

bar pump should be used for all separately 

pumped installations. A twin ended pump is 

required for use with single outlet products.

A universal/negative head type twin ended 

pump (works on both positive and negative head 

conditions) MUST be used with divert products.

The minimum actual capacity of the cold 

water storage cistern should be not less than 

225 litres (50 gallons). The capacity of the hot 

water cylinder must be capable of meeting the 

anticipated demand. 

THIS PRODUCT IS NOT SUITABLE FOR 

USE WITH A SINGLE ENDED PUMP.

Shower Heads

The range of shower heads has been designed 

for use with Smart systems. Installation of 

any shower heads other than these may result 

in poor shower performance. If at any stage 

during installation you have any questions then 

please contact the Aqualisa Customer Service 

Department on 01959 560010 for advice.

Connections

This product incorporates 15mm ‘push-fit’ type 

connections. Tube should be cut using a rotary 

type cutter and lubricated using a silicone 

grease, petroleum jelly, or similar, prior to 

insertion into the fitting. 15mm pipework must 

be used to connect the product.

If plastic pipe is used, the tube insert must 

not increase the tube diameter or extend the 

cut-off length by more than 2mm.

THESE FITTINGS ARE NOT SUITABLE FOR 

STAINLESS STEEL TUBE. COMPRESSION 

FITTINGS MUST NOT BE USED.

Pipe sizing

CHECK PIPE SIZE REQUIREMENTS FOR 

CONNECTIONS TO OUTLETS AND 

ACCESSORIES.

Long pipe runs, on both the inlet and outlet, 

will reduce the flow rate at the shower head, 

22mm pipework should be used on inlets and 

reduced down to 15mm as close to the valve 

as possible to reduce pressure loss and help 

maintain flow rate. If using 15mm pipe, copper 

pipe is preferred. To optimise performance 

minimise the number of elbows used. If long 

pipe runs are unavoidable on the outlet, use 

copper pipe rather than plastic. If plastic pipe is 

used, minimise the number of elbows as the pipe 

inserts are very restrictive.

Flushing

Some modern fluxes can be very corrosive and, 

if left in contact, will attack the working parts 

of this unit. All soldering must be completed 

and the pipework thoroughly flushed out in 

accordance with current local and national 

Water Supply Regulations prior to connection of 

the product.

IMPORTANT INFORMATION

Содержание Visage

Страница 1: ...VISAGE DIGITAL INSTALLATION GUIDE...

Страница 2: ...de 2 CONCEALED COMPONENTS 1 2 EXPOSED COMPONENTS 1 1 Gravity stored water systems only 2 Mains fed and separately pumped water systems only 2 1 Gravity stored water systems only 2 Mains fed and separa...

Страница 3: ...ituations where the ambient temperature is likely to fall below 5 C or rise above 40 C We do not recommend the use of a controller in steam therapy facilities This appliance must be earthed Cables mus...

Страница 4: ...ED PUMP Shower Heads The range of shower heads has been designed for use with Smart systems Installation of any shower heads other than these may result in poor shower performance If at any stage duri...

Страница 5: ...sited it may interfere with digital TV reception Please follow the recommendations below to minimise this effect See recommended layouts below Images of Quartz Smart Valve for illustration only refer...

Страница 6: ...operation and installation of this product the Quartz diverter MUST be installed in one of the orientations shown PLEASE NOTE If installing a diverter please also note all areas ma For installation wi...

Страница 7: ...e to the mounting surface using the screws provided if suitable 4 Attach the supply pipes to the Quartz Smart Valve ensuring that the cold and hot feeds are fitted into the appropriately marked inlets...

Страница 8: ...ign the screws used must be non corrosive Power supply to the Quartz Smart Valve must be switched off before connecting or removing the controller Unscrew the two front cover fixings at the base of th...

Страница 9: ...le plug into the back of the controller ensuring both rubber skirts are recessed into the connection see diagram below using a blunt flat bladed screwdriver or similar tool if required To make a water...

Страница 10: ...truction please ensure the entry hole is neat and unobtrusive otherwise the inner tube could be visible within the showering area Remove ceiling plate if required DO NOT use a compression fitting or s...

Страница 11: ...acket over the rail and support pillar and mark the fixing points Remove the fixing bracket and drill and prepare the fixing points using the fixings provided if suitable Secure the bracket to the wal...

Страница 12: ...kirts are recessed into the connection see diagram below using a blunt flat bladed screwdriver or similar tool if required To make a water tight fitting ensure the rubber seal is no longer visible 12...

Страница 13: ...hat these are located in an accessible dry location and not in the bathroom 1 THIS APPLIANCE MUST BE EARTHED We recommend protecting surface mounted cables in suitable approved conduit to avoid the ri...

Страница 14: ...default Standard Quartz Smart Valve Combi Factory default will be Normal HP this setting must be changed to Combi for temperature stability and optimum performance Balanced High Pressure Standard Quar...

Страница 15: ...allation Guide 15 Wiring Diagram Single Outlet BLENDED WATER COLD HOT 3AMP FUSED ELECTRICAL CONNECTION 10m CABLE 10m CABLE CONTROLLER WIRED REMOTE supplied separately Cables must be run in conduit or...

Страница 16: ...lve Using a flat bladed screwdriver adjust the MAX TEMP ADJUSTMENT control as indicated When the temperature has been set to the desired position carefully replace the Quartz Smart Valve lid and secur...

Страница 17: ...spacer fitting 2 Trim the projecting pipe to a length of 15 22mm measured from the face of the gripper ring using a suitable cutter If a hacksaw is used the pipe end must be carefully de burred and c...

Страница 18: ...he single release button of the handset holder and slide onto the rail assembly 11 Carefully slide the gel hook onto the rail under the handset holder 12 Secure the top rail bracket into position on t...

Страница 19: ...must be passed through the gel hook which has been designed to be utilised as a hose restraint Disengage the pivot clip and remove the pivot from the bottom of the handset Ensure the hose washer is in...

Страница 20: ...e Supply Hot water cylinder Connect A or B Cold feed to cylinder B A NB THE BASE OF THE AQUALISA SMARTVALVETM MUST BE SITED NO HIGHER THAN THE BASE LEVEL OF THE CISTERN Central heating boiler Supply U...

Страница 21: ...max Controller 10m max 10m max Controller Underside of cistern Supply Pressure reducing valve if required Central heating boiler Supply Supply Underside of cistern Hot water cylinder Cold feed to cyli...

Страница 22: ...e temperature dial to the required setting 1 Press the Start Stop button on the controller to turn the shower on 2 The temperature may be adjusted whilst in the shower 4 The LED display will flash unt...

Страница 23: ...reduce the need for chemical descaling in hard water areas your shower head incorporates a clear flow system whereby any scale build up can be broken down by gently rubbing the flexible tips of the j...

Страница 24: ...the dial towards the hottest setting Isolate hot and cold feeds to the Quartz Smart Valve disconnect from the inlet spigots and then using the isolation valve bleed through the hot and cold supplies R...

Страница 25: ...on Logic Module of Quartz Smart Valve If hot water supply is from a combination boiler the Logic module mode MUST be set to COMBI Airlock in water supplies for gravity fed systems only See Air lock in...

Страница 26: ...es enquiries 01 864 3363 Service enquiries 01 844 3212 Aqualisa International Jan Palfijnstraat 26 002 Kortrijk Belgium 8500 Part No 705521 Issue 01 Mar 21 Please note that calls may be recorded for t...

Отзывы: