Visage™ Digital Installation Guide 14
When making any adjustment to the Quartz Smart Valve™
settings the power MUST be isolated. For water economy utilise
the Eco mode.
This is not to be used on Combination boiler
installations, whereby only the Combi mode must be used.
To change the mode, use a flat bladed screwdriver.
Use the table below for water system settings.
Setting Water System Mode
Water System
Valve Type
Setting
Combination Boiler
-
ensure setting is
changed from factory
default
Standard Quartz
Smart Valve™
Combi
Factory default will be Normal HP,
this setting must be changed to
Combi for temperature stability
and optimum performance
Balanced High Pressure
Standard Quartz
Smart Valve™
Normal HP (factory default)
or
Eco HP
Separately Pumped
Gravity
Standard Quartz
Smart Valve™
Normal HP (factory default)
or
Eco HP
Gravity Pumped
Pumped Quartz
Smart Valve™
Normal Gravity (factory default)
or
Eco Gravity
The ECO setting reduces the flow rate, therefore is not recommended when
used in conjunction with combination boiler.
Site conditions can affect temperature settings, installer to adjust as required.
See Controller Commissioning Instructions section.