USER GUIDE - ADJUSTABLE HEAD

Removing the shower head: With the hose still attached, disengage the pivot clip by pushing 
in the outer grey button located on the front of the shower head (near to the hose 
connection). Remove the threaded spigot from the bottom of the handset by using the 
hose to pull clear. To reattach: Ensure the hose washer is in the correct position, tighten the 
threaded spigot into the hose using a suitable hexagonal key, taking care not to over-tighten. 
Reinsert the spigot into the handset and engage the pivot clip prior to placing the handset 
into the handset holder.

1

To select the preferred height for the shower head, press the button to allow the handset 
holder to move up or down the rail.

2

Angular adjustment is made by carefully but firmly pulling 
forwards or pushing back the shower head against the 
knuckle ratchet in the holder.

3

CARING FOR YOUR SHOWER

Over time, your shower may be affected by hard water scaling. To keep your shower working 

effectively, we recommend that you clean your shower regularly.

Your product should be cleaned using only a soft cloth and washing up liquid.

Cleaning the shower head 

To reduce the need for chemical descaling in hard water areas, your shower head incorporates a ‘clear 

flow’ system, whereby any scale build up can be broken down by gently rubbing the flexible tips of the 

jets during use. This procedure should be completed regularly, as often as once a week in some hard 

water areas, as scale build up can affect the spray pattern and cause the shower to perform poorly. 

Failure to descale the shower head can affect the internal seals and may affect the warranty. Should 

descaling of the head using a cleaning agent become necessary, remove the shower head fully and 

immerse in a mild proprietary descaler (e.g. vegetable based or plain white vinegar). Cleaning and 

maintenance should not be undertaken by children without supervision by a person responsible for 

their safety.

DO NOT USE ABRASIVE CLEANERS. It is imperative that descaling is carried out in 
accordance with the manufacturer’s instructions, substances that are not suitable for 
plastics and electroplated surfaces must not be used.

Cleaning tip: To keep your shower effortlessly clean, we recommend drying all shower 
components with a soft cloth after use.

Changing water system? 
If switching from a gravity-fed water system to a mains pressure system (e.g. Combination boiler) you 

will need to change your Quartz Smart Valve™. Contact a member of our Customer Service team for 

further information.

Содержание Visage

Страница 1: ...VISAGE DIGITAL INSTALLATION GUIDE...

Страница 2: ...de 2 CONCEALED COMPONENTS 1 2 EXPOSED COMPONENTS 1 1 Gravity stored water systems only 2 Mains fed and separately pumped water systems only 2 1 Gravity stored water systems only 2 Mains fed and separa...

Страница 3: ...ituations where the ambient temperature is likely to fall below 5 C or rise above 40 C We do not recommend the use of a controller in steam therapy facilities This appliance must be earthed Cables mus...

Страница 4: ...ED PUMP Shower Heads The range of shower heads has been designed for use with Smart systems Installation of any shower heads other than these may result in poor shower performance If at any stage duri...

Страница 5: ...sited it may interfere with digital TV reception Please follow the recommendations below to minimise this effect See recommended layouts below Images of Quartz Smart Valve for illustration only refer...

Страница 6: ...operation and installation of this product the Quartz diverter MUST be installed in one of the orientations shown PLEASE NOTE If installing a diverter please also note all areas ma For installation wi...

Страница 7: ...e to the mounting surface using the screws provided if suitable 4 Attach the supply pipes to the Quartz Smart Valve ensuring that the cold and hot feeds are fitted into the appropriately marked inlets...

Страница 8: ...ign the screws used must be non corrosive Power supply to the Quartz Smart Valve must be switched off before connecting or removing the controller Unscrew the two front cover fixings at the base of th...

Страница 9: ...le plug into the back of the controller ensuring both rubber skirts are recessed into the connection see diagram below using a blunt flat bladed screwdriver or similar tool if required To make a water...

Страница 10: ...truction please ensure the entry hole is neat and unobtrusive otherwise the inner tube could be visible within the showering area Remove ceiling plate if required DO NOT use a compression fitting or s...

Страница 11: ...acket over the rail and support pillar and mark the fixing points Remove the fixing bracket and drill and prepare the fixing points using the fixings provided if suitable Secure the bracket to the wal...

Страница 12: ...kirts are recessed into the connection see diagram below using a blunt flat bladed screwdriver or similar tool if required To make a water tight fitting ensure the rubber seal is no longer visible 12...

Страница 13: ...hat these are located in an accessible dry location and not in the bathroom 1 THIS APPLIANCE MUST BE EARTHED We recommend protecting surface mounted cables in suitable approved conduit to avoid the ri...

Страница 14: ...default Standard Quartz Smart Valve Combi Factory default will be Normal HP this setting must be changed to Combi for temperature stability and optimum performance Balanced High Pressure Standard Quar...

Страница 15: ...allation Guide 15 Wiring Diagram Single Outlet BLENDED WATER COLD HOT 3AMP FUSED ELECTRICAL CONNECTION 10m CABLE 10m CABLE CONTROLLER WIRED REMOTE supplied separately Cables must be run in conduit or...

Страница 16: ...lve Using a flat bladed screwdriver adjust the MAX TEMP ADJUSTMENT control as indicated When the temperature has been set to the desired position carefully replace the Quartz Smart Valve lid and secur...

Страница 17: ...spacer fitting 2 Trim the projecting pipe to a length of 15 22mm measured from the face of the gripper ring using a suitable cutter If a hacksaw is used the pipe end must be carefully de burred and c...

Страница 18: ...he single release button of the handset holder and slide onto the rail assembly 11 Carefully slide the gel hook onto the rail under the handset holder 12 Secure the top rail bracket into position on t...

Страница 19: ...must be passed through the gel hook which has been designed to be utilised as a hose restraint Disengage the pivot clip and remove the pivot from the bottom of the handset Ensure the hose washer is in...

Страница 20: ...e Supply Hot water cylinder Connect A or B Cold feed to cylinder B A NB THE BASE OF THE AQUALISA SMARTVALVETM MUST BE SITED NO HIGHER THAN THE BASE LEVEL OF THE CISTERN Central heating boiler Supply U...

Страница 21: ...max Controller 10m max 10m max Controller Underside of cistern Supply Pressure reducing valve if required Central heating boiler Supply Supply Underside of cistern Hot water cylinder Cold feed to cyli...

Страница 22: ...e temperature dial to the required setting 1 Press the Start Stop button on the controller to turn the shower on 2 The temperature may be adjusted whilst in the shower 4 The LED display will flash unt...

Страница 23: ...reduce the need for chemical descaling in hard water areas your shower head incorporates a clear flow system whereby any scale build up can be broken down by gently rubbing the flexible tips of the j...

Страница 24: ...the dial towards the hottest setting Isolate hot and cold feeds to the Quartz Smart Valve disconnect from the inlet spigots and then using the isolation valve bleed through the hot and cold supplies R...

Страница 25: ...on Logic Module of Quartz Smart Valve If hot water supply is from a combination boiler the Logic module mode MUST be set to COMBI Airlock in water supplies for gravity fed systems only See Air lock in...

Страница 26: ...es enquiries 01 864 3363 Service enquiries 01 844 3212 Aqualisa International Jan Palfijnstraat 26 002 Kortrijk Belgium 8500 Part No 705521 Issue 01 Mar 21 Please note that calls may be recorded for t...