The Dream DCV thermostatic valves are factory set to a safe maximum temperature of 46°C, If required, the
maximum outlet temperature can be adjusted following the procedure below:
1. Set the temperature lever to the mid blend (temperature stop button at 12 o’clock)
position.
Dream DCV valve commissioning
2. Remove the grub screw cover located at the 6 o’clock position.
3. Insert the hexagonal key into the temperature control knob and loosen the grub screw.
4. With the shower running, push the button in and rotate the control knob to the desired temperature.
Turn the shower off.
5. Having rotated the temperature control knob to the desired position, remove the
temperature knob from the valve.
6. Place the temperature knob back onto the valve with the push button in the
12 o’clock position.
7. Secure the control knob onto the valve by reversing the removal procedure detailed
above.