Aquarian Thermo
installation instuctions
page 7
Remove the gripper ring assembly from the
rear of the back plate and ensuring correct
alignment of the gripper rings, slide over the
projecting pipes flush to the wall face.
Cut the supply pipes to their finished length
(18mm – 21mm) using a rotary type cutter.
5
Briefly run the hot and cold supplies to flush out any debris that may be
present in the system.
6
Remove the two fixing screws to release the lower shroud assembly from the
back plate. Carefully remove and set aside.
4
If the valve is being installed for use with a gas
fired instantaneous (multipoint) water heater
or a combination boiler, the cold water flow
regulator must be fitted at this stage by
insertion into the cold water port.
(The flow regulator is supplied in its own pack).
Remove the four cartridge fixing screws and
carefully detach the cartridge assembly from the back plate. Fit the flow
regulator into the cold port fully home, with the central O’ ring facing the
incoming flow. A small length of 15mm pipe may used to facilitate the
installation of this regulator. Refit the cartridge to the back plate using the
four fixing screws ensuring the hot and cold markings on the cartridge are
uppermost.
7
Run a thin bead of silicone sealant in the mastic groove of the back plate.
Using a silicone based lubricant, lubricate the projecting pipe ends before
carefully pushing the shower valve into position fully home. Secure using the
screws provided.
8