Aquarian Thermo
installation instuctions
page 14
Commissioning
The Aquarian Thermo is pre-set to a safe maximum shower temperature. During use, the action of the stop button may be
overridden by depressing it as the temperature control is rotated. Should it be necessary to reset the maximum temperature
position, please observe the following procedures.
1. Ensure that the hot water system is at normal maximum temperature.
2. Turn the temperature control lever to the full cold position (lever fully downwards).
3. Remove the temperature control fixing screw and pull the knob clear.
4. Remove the temperature control lever screws and pull the lever clear.
5. With the cam tooth engaged in the shaft sleeve keyway, turn the sleeve in the appropriate direction to increase or decrease
the maximum temperature. (Each increment equates to approximately 1ºC).
6 Relocate the cam into the cam locking ring and turn the shaft sleeve through 180º (one half turn) to lock the cam down.
7. Depress the red stop button and replace the temperature control knob in the full cold position and secure using the fixing screw.
8. Test the shower by turning it on and slowly increasing the temperature. At the selected point, the button should pop up and
prevent further movement. Repeat the above process if the maximum temperature stop button needs further adjustment.
9. When the stop button is at the desired limit, refit the screw cover in the control knob.
Should the shrouds need to be removed at any time, turn the knob fully clockwise to the off position. Carefully depress the left
hand side of the badge in the middle of the front shroud fascia using a suitable tool taking care not to damage the badge or
the surrounding plated surfaces. The right hand side of the badge will lift clear of the recess enabling you to remove the badge,
giving you access to the small screw fixing the shroud in place. Remove the screw and lift the top shroud assembly clear.
Remove the two fixing screws from the valve assembly and pull the bottom shroud clear.
Should the knobs need to be removed at any time, turn the knob fully downwards to the off position. Remove the screw covers
from the middle of the control knobs with a suitable tool taking care not to damage the surrounding plated areas. Remove the
fixing screws and pull the knob clear.
Should unacceptable damage to the badge occur when removing it from the recess, please contact Aqualisa customer services
who will send a free of charge replacement.
After installation...