7
Installation With an Oscillator (Fig. 2B)
Be sure the support bar is level. Use the U-bolts (Part #125) supplied with the XE Turbo
unit to secure the oscillator to the bar.
Level the oscillator horizontally, so that the base of the oscillator housing is parallel to
the ground. The framework assembly is capable of angling fog output up to 15° upward
or downward.
Remove the nylon stop nuts (Part #32) loosely attached to the oscillator support plate.
Raise the framework assembly directly underneath the oscillator and replace the washers
and nuts. Tighten securely. Use two wrenches when tightening part #117 with part #32
to prevent stress on the oscillator's gear train - one from above to keep the bolt head
stationary and one from below to tighten the nut.
Installation without an Oscillator (Fig. 2A)
Using the U-bolts provided, secure the framework assembly to the
desired 1" support bar. Tighten securely. Support bar can be placed in
line with the fan or perpendicular to it. The second nut (Part #32) can
be secured on top of the first nut (Part #154) to provide anti-vibration
protection and increase installation security.
A
Framework
Assembly
Support Bar
(not provided)
Support Bar
(not provided)
I
NSTALLATION
Fig. 2
USING A LADDER TO HANG THE TURBO XE IS DANGEROUS.
USE PROPER LIFTING EQUIPMENT LIKE A SCISSOR LIFT.
B
DANGER
Pivot Joint
1/4-20 U-bolt SST
(#125)
#53
#126
#154
#32
#53
#126
#154
#117
#32
Oscillator
1/4-20 U-bolt SST
(#125)
#32
Framework
Assembly