Appedix A – SubConn Connector
SubConn
®
hand ling instructions
Follow these instructions carefully to ensure correct use of your
SubConn
®
connectors.
■
Always apply grease before mating (see next page)
■
Disconnect by pulling straight, not at an angle
■
Do not pull on the cable and avoid sharp bends at cable entry
■
When using a bulkhead connector, ensure that there are no
angular loads
■
Do not over-tighten the bulkhead nuts
■
SubConn
®
connectors should not be exposed to extended
periods of heat or direct sunlight. If a connector becomes
very dry, it should be soaked in fresh water before use
Handling
Untagged cable and pigtail colour coding
2 - 25 pin connectors (excluding 3 pin connectors):
1 Black
7 White / Black
13 Red / White
2 White
8 Red / Black
14 Green / White
3 Red
9 Green / Black
15 Blue / White
4 Green
10 Orange / Black
16 Black / Red
5 Orange
11 Blue / Black
17-25 Tagged numbering
6 Blue
12 Black / White
3 pin connectors:
1 Black
2 White
3 Green