INTRODUCTION

Contents

Page 2

TECHNICAL SPECIFICATION

Page 2

INSTALLATION & FITTING

Page 5

TYPICAL INSTALLATION (FIGURE 1) 

Page 4

AUTO FLUSHING GENERATOR (FIGURE 2)

Page 7

DESCALING

Page 11

Please read all of the instructions carefully before commencing installation or using the facility.

PROBLEM SOLVING GUIDE

Page 13

INDICATORS

Page 12

OPERATING INSTRUCTIONS

Page 9

COMMERCIAL STEAM GENERATOR 

Installation Instructions

Содержание AQUA-STEAM GENERATOR 1

Страница 1: ...N FIGURE 1 Page 4 AUTO FLUSHING GENERATOR FIGURE 2 Page 7 DESCALING Page 11 Please read all of the instructions carefully before commencing installation or using the facility PROBLEM SOLVING GUIDE Pag...

Страница 2: ...size and materials used in the construction of the steam enclosure Each model of steam generator has three power settings See table below This allows our generators to cover various sizes of steam roo...

Страница 3: ...STEAM OUTLET 22mm max length 20 Metres pipe must be lagged adequately NOTE BJ18 24A is supplied with two steam outlets If pipe is longer than 10 Metres add an extra kW TWO STEAM SAFETY FEATURES IN 1 M...

Страница 4: ...Page 4 TYPICAL INSTALLATION FIGURE 1 FIGURE 1 PLEASE NOTE THIS DIAGRAM IS NOT TO SCALE...

Страница 5: ...ess is greater than 100 ppm it is recommended that a monospheric water softener be incorporated to supply the generator especially if the unit is to be in frequent use Alternately inspect the unit for...

Страница 6: ...ig 2 into connector detail 6 Fig 2 By tightening the three screws the machine will be converted into single phase operation The BJ18 24 is three phase only When connecting cables to power supply it is...

Страница 7: ...Page 7 AUTO FLUSHING GENERATOR FIGURE 2 FIGURE 2...

Страница 8: ...W 7 Safety Cut Out 8 PCB Board Fuse 9 Terminal Block For KW Change 10 Terminal Block KW Change Pins 10a Set Of Probes Aqua Steam Generator 11 Indicator Heater ON 12 Indicator Water ON 13 Indicator Pow...

Страница 9: ...nimum ON time is two hours COMPUTER LINK MANAGEMENT SYSTEM optional extra This link will allow you to switch the generator ON or OFF from a computer but the control switch must be positioned in timer...

Страница 10: ...If the water softener is working correctly removal of water deposits will not normally be necessary When the steam generator has cooled down drain the generator by holding the DUMP SWITCH on the contr...

Страница 11: ...in the generator for as long as instructed Typically 5 24 hours 4 Flush the generator thoroughly to ensure that all traces of de scalent are removed Note that with the tank empty it is useful to unscr...

Страница 12: ...s If adjustment is required then press the up and down arrows as necessary Once set the display will resort to displaying the actual temperature after approximately 5 sec STEAM GENERATOR INDICATORS Th...

Страница 13: ...d steam outlet Consult installer NOTES THE MOST FREQUENT CAUSE OF PROBLEMS ARE 1 Insufficient water water pressure low or the supply interrupted by other services i e showers pumps etc Water inlet blo...

Страница 14: ...input has not become blocked with swarf or sediment 4 The steam pipe or the steam outlet has not become blocked WARRANTY The supplier may exchange recondition or repair the unit on a return to base s...