Aqua AQUA-STEAM GENERATOR 1 Скачать руководство пользователя страница 6

Page 6

STAGE SIX: - Fitting 12v Electronic Attendant Control9

This control must be fitted in an easily accessible dry place for the operation of the attendant. When the control 

is fitted to the wall then connect plugs coming from the control to the sockets on relay board inside left hand 

of generator box. NOTE extension leads are available if required. Also make sure exposed connectors are 

protected with water proof tape. 

STAGE SEVEN: - Computer Management Link 

You only need to connect a 2 wire lead with a gland inside lower left hand of attendant control. These wires 

must go to a volt free contact at the computer, when contact is made (closed) generator will start, when contact 

is (open) generator will stop. NOTE: control switch must be on timer mode and the timer switch “OFF” to 

synchronies with computer. This function is available as standard on the AKW control but only by special order 

on the BKW control. 

STAGE EIGHT: - Power (Kilowatt) selection for BJ6-12 & BJ18-24

For BJ6-12 the fixed minimum power is 6kW. To increase to 9kW insert link pin (detail 10 Fig 2) and to increase to 

12kW also insert link pin (detail 10A Fig 2). For model BJ18-24 the minimum fixed power is 18kW. To increase to 

21KW fit link pin (detail 10 Fig 2), to increase to 24KW fit link pin (detail 10A Fig 2). Link pins are to prevent power 

being accidentally increased. Cable should be adequately sized to suit the power requirement. Note: setting the 

generator on a higher power than necessary may result in the cubicle remaining for relatively long periods at a 

temperature above the set point with no steam. Only use the minimum power necessary. 

STAGE NINE: - Connection to Power supply

The BJ6-12 is set for three phase but can be modified to single phase use by inserting a link connector supplied 

(detail 6A Fig 2) into connector (detail 6 Fig 2). By tightening the three screws the machine will be converted into 

single phase operation. The BJ18-24 is three phase only. When connecting cables to power supply it is advised 

that conduit be used and connected via hole (detail 6B Fig 2) with the appropriate fitting. 220-240v AC. for single 

phase, 415v AC. for three phases 50-60Hz. The steam generator must be earthed and connected to a residual 

current circuit breaker with a minimum of 30 mille Amps sensitivity and connected through an isolating switch 

with minimum of 3mm breakage across all poles. The correct fuse must be fitted for the power selected. For 

technical specification see page 2. NOTE all mains connections must be thoroughly tightened and it is good 

practice to re-tighten all power connections within the generator since copper conductors may have “eased 

back’’ in their terminals in transit.

 

STAGE TEN: - Essence Doser unit (optional extra)

This machine is provided with a 220-240v AC. 5 amp fused terminal connector (detail 18) and PG7 cable gland 

(detail 18A) for essence doser connection, this will energies when steam is produced. For further details contact 

your supplier.

STAGE ELEVEN: - Commissioning Generator

Re-check that the unit is installed in accordance with the instructions before switching mains power on. Please 

check that the water supply is “ON” with sufficient pressure 0.5 bar, (3 meters head). Switch power “ON” and 

you will see a green light on the generator and an intermittent one on the AKW attendant control or a further 

steady green light on the BKW control (that means the generator is ready to start) now follow the operating 

instructions. Once the generator is operating switch off and drain the generator to clean plumbing flux etc from 

inside. Do this twice and finally check for leaks. If you need any further information please do not hesitate to 

contact our technical department.

Please leave instructions with client and demonstrate how to de-scale the unit.

Содержание AQUA-STEAM GENERATOR 1

Страница 1: ...N FIGURE 1 Page 4 AUTO FLUSHING GENERATOR FIGURE 2 Page 7 DESCALING Page 11 Please read all of the instructions carefully before commencing installation or using the facility PROBLEM SOLVING GUIDE Pag...

Страница 2: ...size and materials used in the construction of the steam enclosure Each model of steam generator has three power settings See table below This allows our generators to cover various sizes of steam roo...

Страница 3: ...STEAM OUTLET 22mm max length 20 Metres pipe must be lagged adequately NOTE BJ18 24A is supplied with two steam outlets If pipe is longer than 10 Metres add an extra kW TWO STEAM SAFETY FEATURES IN 1 M...

Страница 4: ...Page 4 TYPICAL INSTALLATION FIGURE 1 FIGURE 1 PLEASE NOTE THIS DIAGRAM IS NOT TO SCALE...

Страница 5: ...ess is greater than 100 ppm it is recommended that a monospheric water softener be incorporated to supply the generator especially if the unit is to be in frequent use Alternately inspect the unit for...

Страница 6: ...ig 2 into connector detail 6 Fig 2 By tightening the three screws the machine will be converted into single phase operation The BJ18 24 is three phase only When connecting cables to power supply it is...

Страница 7: ...Page 7 AUTO FLUSHING GENERATOR FIGURE 2 FIGURE 2...

Страница 8: ...W 7 Safety Cut Out 8 PCB Board Fuse 9 Terminal Block For KW Change 10 Terminal Block KW Change Pins 10a Set Of Probes Aqua Steam Generator 11 Indicator Heater ON 12 Indicator Water ON 13 Indicator Pow...

Страница 9: ...nimum ON time is two hours COMPUTER LINK MANAGEMENT SYSTEM optional extra This link will allow you to switch the generator ON or OFF from a computer but the control switch must be positioned in timer...

Страница 10: ...If the water softener is working correctly removal of water deposits will not normally be necessary When the steam generator has cooled down drain the generator by holding the DUMP SWITCH on the contr...

Страница 11: ...in the generator for as long as instructed Typically 5 24 hours 4 Flush the generator thoroughly to ensure that all traces of de scalent are removed Note that with the tank empty it is useful to unscr...

Страница 12: ...s If adjustment is required then press the up and down arrows as necessary Once set the display will resort to displaying the actual temperature after approximately 5 sec STEAM GENERATOR INDICATORS Th...

Страница 13: ...d steam outlet Consult installer NOTES THE MOST FREQUENT CAUSE OF PROBLEMS ARE 1 Insufficient water water pressure low or the supply interrupted by other services i e showers pumps etc Water inlet blo...

Страница 14: ...input has not become blocked with swarf or sediment 4 The steam pipe or the steam outlet has not become blocked WARRANTY The supplier may exchange recondition or repair the unit on a return to base s...

Отзывы: