COMPUTER LINK MANAGEMENT SYSTEM
This link will allow you to switch the generator on or off from your computer but the timer switch must be in the
off position. This function is only available by special order.
TEMPERATURE ADJUST
The digital thermostat displays the temperature at the sensor in the steam room, to display the set point press
and hold the thermometer button. Should the set point need adjustment continue to hold the thermometer
button and at the same time use the up or down arrow to select the required temperature. Release all buttons.
START UP DISCHARGE
The BKW control is designed so that it may also be used in conjunction with an Automatic Descaler. When
descaling is completed and the generator restarts a brief heating cycle (10 seconds approx) is initiated followed
by a 4 minute discharge (approx) and delay before the generator refills and starts to heat up. This discharge can
be over-ridden by using the on/off switch on the bottom right of the control, turning it on, off and on again.
REMOVAL OF WATER DEPOSITS
If a water softener is fitted always ensure that it is not allowed to function without salt and that it only back
washes at a time when the steam generator is not in use. If the water softener is working correctly removal of
water deposits will not normally be necessary. When the steam generator has cooled down drain the generator
by holding the “DUMP SWITCH” on the control isolate the machine at the main power switch. Then place a
container of minimum of 5ltr capacity under the lower access cap. Remove the access cap by hand, turning anti-
clockwise, releasing the water residue. With the brush provided clean inside the bottom of the tank to remove
any flakes of scale. Replace access cap hand tight only; please be careful not to cross the threads. Check for
leaks. Switch on mains power and your regular maintenance is now complete.
SCALE
Scale is the primary concern in heavily used generators and an auto de-scale unit is available for use in
conjunction with th BKW control and commercial generators. The auto de-scale adds descaler to the generator
when it is switched OFF at night. It is a feature of the BKW control that at start up from the time clock the
generator will be instructed to heat for a few seconds and then dump the entire contents of the tank over a 4
minute period, to remove any descaler that may have been added. This ensures that the unit contains fresh
water before steaming begins. If an auto de-scale unit is not fitted or during testing, the 4 minute delay period
can be overridden by switching the control ON/OFF switch from ON to OFF and back to ON again.