MAINTENANCE CONTINUED
How To Clean The Valve Continued
7. Tum pump off. Using a Phillips screwdriver and 10mm wrench, remove the screws
from the top of the valve.
8. Remove cover from valve.
9. Rinse out inside of valve and check for any debris lodged under spider
gasket. Be sure spider gasket is seating in the groove properly reposition
if necessary.
10. Re-attach top of valve.
11. Tum pump on. Check if leak has stopped. If leak continues you will need to replace your
spider gasket assembly.
�--
,,.
-==-=./'·�