© 2002 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123
36
Series SC
Installation, Operation,and
Maintenance Manual
When reinstalling the gray arrow handles be sure that:
1.
O-rings on both rotors face to the right when being viewed from
the front of the control valve when the handle pointers are lined
up with the control valve body arrows; or
2.
Arrows point toward each other in the bypass position.
Since the handles can be pulled off, they could be accidentally rein-
stalled 180˚ from their correct orientation. To install the gray arrow
handles correctly, keep the handles pointed in the same direction as the
arrows engraved on the control valve body while tightening the bypass
valve caps.
After completing any valve maintenance, press and hold “NEXT” and “REGEN” buttons for 3 seconds or unplug power
source jack (black wire) and plug back in. This resets the electronics and establishes the service piston position. The
display should flash all wording, then flash the software version (e.g. 154) and then reset the valve to the service position.
Service Guide
After completing any valve
maintenance, press and hold
“NEXT” and “REGEN” buttons
for 3 seconds or unplug power
source jack (black wire) and plug
back in.
Tip: