© 2002 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123
14
Series SC
Installation, Operation,and
Maintenance Manual
Programming
1.
Press “NEXT” and “Up” simultaneously for 3 seconds.
2.
Hardness: Set the amount of hardness in grains per gallon of hardness. Use
the “Total Compensated Hardness” number from page 6. Use the “Up” and
“Down” buttons to set the hardness number. Press “NEXT” to go to the next
step.
3.
Day Override: Maximum allowable days between regenerations. Can be set to
“OFF” to regenerate based only on gallons used. If a number is set (1-28),
regeneration is based on gallons unless the specified number of days is
reached. The systems then regenerates at the programmed time and the
gallon capacity is reset. Press “NEXT” to go to the next step.
4.
Next Regeneration Time (hour): Set the hour of day for regeneration using the
“Up” or “Down” buttons. Press “NEXT” to set minutes.
5.
Next Regeneration Time (minutes): Set the minutes of day for regeneration
using the “Up” or “Down” buttons. Press “NEXT” to exit program and return to
normal operation.
Installer Displays/Settings:
Return to
Normal Operation
Note:
To initiate a manual regeneration immediately,
press and hold the “REGEN” button for three seconds.
The system will begin to regenerate immediately.