SECTION II.   SPECIFICATIONS 

TABLE A – qUALIFIED SySTEM PERFORMANCE 

  Because the performance of an R.O. Membrane is highly dependent upon pressure, temperature and TDS, the following 

should be used for comparison purposes only.

 

U.S. 

Metric

Membrane Production

1

 

41-53 gpd 

155–201 lpd

Membrane TDS Reduction

1

 

96% minimum 

96% minimum

System Production² 

14 gpd 

53 lpd

Recovery Rating

38% 

38%

Efficiency Rating

22% 

22%

TDS Reduction² 

90%+ typical 

90%+ typical

Drain (reject water) Flow 

3–5 x product flow 

3–5 x product flow

Empty Storage Tank Precharge 

5–7 psig air 

35–48 kPa air

Storage Tank Capacity

1.8 gallons 

 

6.8 liters

1

  Industry standards measure R.O. Membranes performance with no backpressure on the product water, at 65 psig (448kPa) and 77°F  

(25°C). Further  conditions on the above are 250 ppm TDS.  Production rate and TDS reduction figures are for a new Membrane that   

has been rinsed for 24 hours. The production  rate of a new Membrane can decrease by 10% per year or more, depending upon the    

scaling and fouling tendencies of the Feed Water. 

2

  Measured at 50 psig, 77°±2° F, 750±40 mg/l TDS per section 6 of NSF/ANSI Standard 58. 

Recovery rating means the percentage 

of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when 

the system is operated without a storage tank or when the storage tank is bypassed.  Efficiency rating means the percentage 

of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that 

approximate typical daily usage. This reverse osmosis system contains a replaceable component critical to the efficiency of 

the system. Replacement of the reverse osmosis component should be with one of identical specifications, as defined by the 

manufacturer, to assure the same efficiency and contaminant reduction performance.

TABLE B – RECOMMENDED OPERATING LIMITS FOR FEED WATER

Specifications   

T.F.C. Membrane

Water Pressure    

40–100 psig (280–690 kPa)

TDS   

2000 ppm (also mg/l) max.

Temperature    

40–100°F (4–38°C) 

pH    

4–11 (optimum rejection at pH 7.0 - 7.5)

Hardness    

Less than 10 gpg (170 mg/l) or soften

Iron    

Less than 0.1 ppm (also mg/l)

Manganese    

Less than 0.05 ppm (also mg/l)

Hydrogen Sulfide    

None

Chlorine    

See note

Bacteria    

Must be potable**

NOTE: Chlorine will damage a T.F.C. Membrane. The Activated Carbon Prefilter has been designed to reduce chlorine from the 

incoming water. Change filter every 6 to 12 months, more often if the water contains more than 1 ppm chlorine.

**DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY, WITHOUT ADEQUATE 

 

DISINFECTION BEFORE OR AFTER THE SYSTEM.

Содержание AQPC-35

Страница 1: ...t NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet 7785 East U S Highway 36 Avon Indiana 46123 317 272 3000 Installation Operation and Maintenance Manual AQ...

Страница 2: ...eceiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital immunodeficiencies The EPA has stated th...

Страница 3: ...and is less susceptible to fouling by particulate matter turbidity and colloidal materials ACTIVATED CARBON POST FILTER The product water from the Holding Tank passes through the Activated Carbon Post...

Страница 4: ...is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influen...

Страница 5: ...clude wood screws or machine screws and nuts for mounting the manifold or concrete anchors for hanging on basement wall additional tubing or tube connectors plastic wire ties for organizing tubing Fig...

Страница 6: ...ctivated carbon post filter housing Reverse osmosis membrane housing sediment carbon prefilter housing BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper ai...

Страница 7: ...open area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the m...

Страница 8: ...ller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch Clean away any chips Install the punch and tighten the nut to cut the hole Deburr any...

Страница 9: ...OLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fitting Push the Black 3 8 Polytube onto th...

Страница 10: ...you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard steel or brass tubing supply line The supply line should no...

Страница 11: ...cket can be used as a template Install the screws and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRICTOR B L U E 2 Locate the Red Feed Water Tubing...

Страница 12: ...mly tighten the Housings hand tight only Slowly open the Feed Water Saddle Valve turning counter clockwise As soon as the water begins to come out of the Dispensing Faucet close the Faucet Let stand f...

Страница 13: ...arbon Prefilter and the Activated Carbon Post Filter Housings Discard the filters 3 Wash the inside of the Housings using a mild detergent and a soft cloth Do not use abrasive cleaners or pads Thoroug...

Страница 14: ...tioning Replace ASO Valve components Low pressure at the Dispensing Faucet Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding Tank is too low Empty water from Hol...

Страница 15: ...lding Tank Clean flush and sanitize the system Replace the filters The Product Water and Drain Water lines are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Water to remov...

Страница 16: ...16 MADE IN USA 1 2 3 4 5 6 7 8 9 11 12 13 14 18 19 20 Exploded View Parts List 21 Water Quality Test Kit 22 Nitrate Nitrite Test Kit 15 17 10 15...

Страница 17: ...RO Membrane 50 gpd 189 lpd 13 S3069 Housing O Ring 14 S3010 Housing 15 PK A6TEU4 MG 1 4 Post X 3 8 Polytube Elbow 17 S2116 5 Drain Restrictor 50 GPD 189 lpd Green 18 S7125 Activated Carbon Post Filter...

Страница 18: ...18 NOTES...

Страница 19: ...19 NOTES...

Страница 20: ...s not cover the disposable sediment and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The...

Отзывы: