background image

10

FEED WATER SADDLE VALVE 

Cold Water

Line

Saddle

Valve

Handle

Insert

Plastic

Ferrule

Red Tubing To

Manifold

Inlet

Compression

Nut

Tightening

Screw

Reversible

Back Plate

Figure 3

B.  Feed Water Saddle Valve Installation 

  Decide on location. Do NOT connect to a hot water 

feed line. If you are not sure of the supply, run the 

hot water and feel the supply piping. Water over 

100°F may cause permanent damage to the R.O. 

Membrane. (Refer to Fig. 3.) 
1.  Shut off the water supply and drain the line.
2a. To install on (soft) Copper Tubing supply  

line:
•Turn the Handle of the Feed Water Saddle 

Valve counter clockwise (outward) until the 

lance does not protrude from the gasket. It 

may have to be pushed in. 

•Assemble the Feed Water Saddle Valve on the 

tubing.

– for 

3

/

8

" OD tubing use the back plate side with 

the small groove to prevent distortion of the 

tubing. 

– for larger tubing (up to 

5

/

8

" OD) use the large 

groove of the back plate. 

•Assemble and tighten the brass screw. 
•To pierce the tubing, turn the Valve Handle 

fully clockwise (inward). A small amount of 

water may escape from the outlet until it is 

fully pierced. 

•When you feel the Valve Handle firmly seated 

in the clockwise direction, the copper tube is 

pierced and the valve is closed.

2b. To install on (hard) steel or brass tubing supply 

line. 
•The supply line should now be drained. Use a 

battery powered or properly grounded drill to 

avoid shock hazard. 

•Drill a 

3

/

16

" hole in the supply line; (do not drill 

through the opposite wall). 

•Turn the handle to expose the lance no more 

than 

3

/

16

" beyond the rubber gasket. 

•Place the body of the valve over the hole so 

that the lance fits into the hole. 

•Assemble and tighten the brass screw. 
•Turn the Valve Handle clockwise (inward) until 

firmly seated. The valve is closed. 

3.  With the Feed Water Saddle Valve closed, 

open the sink faucet and the water supply and 

allow the water to run for a few minutes to flush 

any debris caused by the installation. 
•Close the faucet and check the Feed Water 

Saddle Valve for leaks.

3/8" DRAIN CLAMP ASSEMBLy

 

Drain Clam

p

Fr

ont Plate

Drain Pipe

1/4" Nu

t

1/4" Screw

Drain Clam

p

Bac

k Plate

Blac

k Drain 

Tubing

Figure 4

 

C.  Drain Clamp Installation 

  Choose the drain outlet location per Sec. III, C.5. 
  The following are instructions for discharging into 

the sink drain pipe. (Refer to Fig. 1, page 5.) 
1.  Position the Drain Clamp on the sink drain pipe 

above the drain trap. Allow room for drilling. 

Tighten securely. 

Содержание AQPC-35

Страница 1: ...t NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet 7785 East U S Highway 36 Avon Indiana 46123 317 272 3000 Installation Operation and Maintenance Manual AQ...

Страница 2: ...eceiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital immunodeficiencies The EPA has stated th...

Страница 3: ...and is less susceptible to fouling by particulate matter turbidity and colloidal materials ACTIVATED CARBON POST FILTER The product water from the Holding Tank passes through the Activated Carbon Post...

Страница 4: ...is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influen...

Страница 5: ...clude wood screws or machine screws and nuts for mounting the manifold or concrete anchors for hanging on basement wall additional tubing or tube connectors plastic wire ties for organizing tubing Fig...

Страница 6: ...ctivated carbon post filter housing Reverse osmosis membrane housing sediment carbon prefilter housing BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper ai...

Страница 7: ...open area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the m...

Страница 8: ...ller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch Clean away any chips Install the punch and tighten the nut to cut the hole Deburr any...

Страница 9: ...OLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fitting Push the Black 3 8 Polytube onto th...

Страница 10: ...you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard steel or brass tubing supply line The supply line should no...

Страница 11: ...cket can be used as a template Install the screws and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRICTOR B L U E 2 Locate the Red Feed Water Tubing...

Страница 12: ...mly tighten the Housings hand tight only Slowly open the Feed Water Saddle Valve turning counter clockwise As soon as the water begins to come out of the Dispensing Faucet close the Faucet Let stand f...

Страница 13: ...arbon Prefilter and the Activated Carbon Post Filter Housings Discard the filters 3 Wash the inside of the Housings using a mild detergent and a soft cloth Do not use abrasive cleaners or pads Thoroug...

Страница 14: ...tioning Replace ASO Valve components Low pressure at the Dispensing Faucet Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding Tank is too low Empty water from Hol...

Страница 15: ...lding Tank Clean flush and sanitize the system Replace the filters The Product Water and Drain Water lines are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Water to remov...

Страница 16: ...16 MADE IN USA 1 2 3 4 5 6 7 8 9 11 12 13 14 18 19 20 Exploded View Parts List 21 Water Quality Test Kit 22 Nitrate Nitrite Test Kit 15 17 10 15...

Страница 17: ...RO Membrane 50 gpd 189 lpd 13 S3069 Housing O Ring 14 S3010 Housing 15 PK A6TEU4 MG 1 4 Post X 3 8 Polytube Elbow 17 S2116 5 Drain Restrictor 50 GPD 189 lpd Green 18 S7125 Activated Carbon Post Filter...

Страница 18: ...18 NOTES...

Страница 19: ...19 NOTES...

Страница 20: ...s not cover the disposable sediment and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The...

Отзывы: