10
FEED WATER SADDLE VALVE
Cold Water
Line
Saddle
Valve
Handle
Insert
Plastic
Ferrule
Red Tubing To
Manifold
Inlet
Compression
Nut
Tightening
Screw
Reversible
Back Plate
Figure 3
B. Feed Water Saddle Valve Installation
Decide on location. Do NOT connect to a hot water
feed line. If you are not sure of the supply, run the
hot water and feel the supply piping. Water over
100°F may cause permanent damage to the R.O.
Membrane. (Refer to Fig. 3.)
1. Shut off the water supply and drain the line.
2a. To install on (soft) Copper Tubing supply
line:
•Turn the Handle of the Feed Water Saddle
Valve counter clockwise (outward) until the
lance does not protrude from the gasket. It
may have to be pushed in.
•Assemble the Feed Water Saddle Valve on the
tubing.
– for
3
/
8
" OD tubing use the back plate side with
the small groove to prevent distortion of the
tubing.
– for larger tubing (up to
5
/
8
" OD) use the large
groove of the back plate.
•Assemble and tighten the brass screw.
•To pierce the tubing, turn the Valve Handle
fully clockwise (inward). A small amount of
water may escape from the outlet until it is
fully pierced.
•When you feel the Valve Handle firmly seated
in the clockwise direction, the copper tube is
pierced and the valve is closed.
2b. To install on (hard) steel or brass tubing supply
line.
•The supply line should now be drained. Use a
battery powered or properly grounded drill to
avoid shock hazard.
•Drill a
3
/
16
" hole in the supply line; (do not drill
through the opposite wall).
•Turn the handle to expose the lance no more
than
3
/
16
" beyond the rubber gasket.
•Place the body of the valve over the hole so
that the lance fits into the hole.
•Assemble and tighten the brass screw.
•Turn the Valve Handle clockwise (inward) until
firmly seated. The valve is closed.
3. With the Feed Water Saddle Valve closed,
open the sink faucet and the water supply and
allow the water to run for a few minutes to flush
any debris caused by the installation.
•Close the faucet and check the Feed Water
Saddle Valve for leaks.
3/8" DRAIN CLAMP ASSEMBLy
Drain Clam
p
Fr
ont Plate
Drain Pipe
1/4" Nu
t
1/4" Screw
Drain Clam
p
Bac
k Plate
Blac
k Drain
Tubing
Figure 4
C. Drain Clamp Installation
Choose the drain outlet location per Sec. III, C.5.
The following are instructions for discharging into
the sink drain pipe. (Refer to Fig. 1, page 5.)
1. Position the Drain Clamp on the sink drain pipe
above the drain trap. Allow room for drilling.
Tighten securely.
Содержание AQPC-35
Страница 18: ...18 NOTES...
Страница 19: ...19 NOTES...