11

2.  Use a battery powered or properly grounded 

drill. Using the Clamp port as a drill guide,  drill 

7

/

32

" hole through the wall of the drain pipe. 

Do NOT penetrate the opposite side of the 

pipe. 

3.  Locate the 

3

/

8

" Black Drain Tubing connected to 

the Dispensing Faucet. Route the tubing to the 

Drain Clamp and trim to length. 

 

NOTE:

 When cutting the polytubing make  

clean, square cuts, failing to do so could result 

in poor connections and possible leaks. 

 

CAUTION:

 The lowest point of the line should 

be the point of connection to the Drain Clamp. 

There should be no sag in the line as this may 

cause excessive noise as the reject water is 

flowing to drain.
•Refer to Fig. 4. Insert the tubing into the Drain 

Clamp. Make sure the tubing is pressed 

all the way in to create a pressure-tight 

connection.

NOTE: If you want to pull the tubing out for 

some reason, push the ring around the tubing 

in and pull the tubing out.

D.  R.O. Manifold Assembly Installation 

  Locate the site per Sec. III, C.3. Various installation 

sites will require different types of mounting 

fasteners; be sure the fastener selected will 

provide a firm, solid mounting. A support panel 

may be necessary on thin cabinet walls or to span 

between wall studs on particle board or drywall. 

  Do not drill through exterior cabinet walls or leave 

sharp wood screw points exposed in readily 

accessible cabinet interiors. 

  The close proximity of a dishwasher or a trash 

compactor may require special fabrication of a 

mounting plate. 
1.  The mounting bracket will accept either #10 

or #12 (5mm) mounting screws spaced on 

6" (15 cm) centers. Allow at least 4" (10 cm) 

of clearance beneath the filter housings to 

accommodate filter changes. Mark the two 

locations (the bracket can be used as a 

template). Install the screws and tighten them 

until the heads are about 

5

/

8

" from the wall.

RED

BLACK

YELLOW

IN

DRAIN

OUT

DRAIN 

RESTRICT

OR

B

L

U

E

2.  Locate the ¼" Red Feed Water Tubing. 

Remove the red plug from the fitting labeled 

“In” on the manifold and insert the tubing. 

The fittings will grab the tubing and seal it in 

place. Make sure the tubing is pressed all the 

way in to create a pressure tight connection. 

Reference the special supplement sheet in 

the carton for proper connection of all tubing 

and removal of plugs. Run the tubing along its 

course to the Feed Water Saddle Valve, trim to 

length. (Refer to Fig. 1, page 5.) 

  Refer to Fig. 3. To the end of the red polytube 

install the Compression Nut, the  Plastic 

Ferrule, and the Brass Insert. Connect to the 

Feed Water Saddle Valve.

3.  Locate the ¼" Black Drain Tubing connected 

to the Dispensing Faucet. The end of the Black 

Drain Tubing that should be inserted into the 

“Drain” port on the manifold will have a green 

drain restrictor in it. Remove the black plug 

from the fitting labeled “Drain” on the manifold 

and insert the tubing. Allow the tubing to relax, 

then press firmly again to insure proper seating.

4.  Locate the 3/8" yellow tubing. Remove the 

yellow plug from the fitting on top of the 

manifold labeled "Tank" and insert the tubing. 

(Refer to Fig. 1, page 5.)

5.  Locate the 3/8" Blue Product Water Tubing 

connected to the Dispensing Faucet. Remove 

the blue plug from the elbow connected to the 

fitting labeled “Out” on the manifold, trim the 

tubing to length and insert the tubing. The fitting 

will grab the tubing and seal it in place. Make 

sure the tubing is pressed all the way in past 

the o-ring to create a pressure tight connection. 

 

NOTE:

 If you want to pull the tubing out for 

some reason, push the ring around the tubing 

in and pull the tubing out. 

6.  Hang the Manifold Assembly on the mounting 

screws and tighten. DO NOT OVERTIGHTEN.

Содержание AQPC-35

Страница 1: ...t NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet 7785 East U S Highway 36 Avon Indiana 46123 317 272 3000 Installation Operation and Maintenance Manual AQ...

Страница 2: ...eceiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital immunodeficiencies The EPA has stated th...

Страница 3: ...and is less susceptible to fouling by particulate matter turbidity and colloidal materials ACTIVATED CARBON POST FILTER The product water from the Holding Tank passes through the Activated Carbon Post...

Страница 4: ...is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influen...

Страница 5: ...clude wood screws or machine screws and nuts for mounting the manifold or concrete anchors for hanging on basement wall additional tubing or tube connectors plastic wire ties for organizing tubing Fig...

Страница 6: ...ctivated carbon post filter housing Reverse osmosis membrane housing sediment carbon prefilter housing BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper ai...

Страница 7: ...open area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the m...

Страница 8: ...ller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch Clean away any chips Install the punch and tighten the nut to cut the hole Deburr any...

Страница 9: ...OLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fitting Push the Black 3 8 Polytube onto th...

Страница 10: ...you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard steel or brass tubing supply line The supply line should no...

Страница 11: ...cket can be used as a template Install the screws and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRICTOR B L U E 2 Locate the Red Feed Water Tubing...

Страница 12: ...mly tighten the Housings hand tight only Slowly open the Feed Water Saddle Valve turning counter clockwise As soon as the water begins to come out of the Dispensing Faucet close the Faucet Let stand f...

Страница 13: ...arbon Prefilter and the Activated Carbon Post Filter Housings Discard the filters 3 Wash the inside of the Housings using a mild detergent and a soft cloth Do not use abrasive cleaners or pads Thoroug...

Страница 14: ...tioning Replace ASO Valve components Low pressure at the Dispensing Faucet Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding Tank is too low Empty water from Hol...

Страница 15: ...lding Tank Clean flush and sanitize the system Replace the filters The Product Water and Drain Water lines are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Water to remov...

Страница 16: ...16 MADE IN USA 1 2 3 4 5 6 7 8 9 11 12 13 14 18 19 20 Exploded View Parts List 21 Water Quality Test Kit 22 Nitrate Nitrite Test Kit 15 17 10 15...

Страница 17: ...RO Membrane 50 gpd 189 lpd 13 S3069 Housing O Ring 14 S3010 Housing 15 PK A6TEU4 MG 1 4 Post X 3 8 Polytube Elbow 17 S2116 5 Drain Restrictor 50 GPD 189 lpd Green 18 S7125 Activated Carbon Post Filter...

Страница 18: ...18 NOTES...

Страница 19: ...19 NOTES...

Страница 20: ...s not cover the disposable sediment and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The...

Отзывы: