11
2. Use a battery powered or properly grounded
drill. Using the Clamp port as a drill guide, drill
a
7
/
32
" hole through the wall of the drain pipe.
Do NOT penetrate the opposite side of the
pipe.
3. Locate the
3
/
8
" Black Drain Tubing connected to
the Dispensing Faucet. Route the tubing to the
Drain Clamp and trim to length.
NOTE:
When cutting the polytubing make
clean, square cuts, failing to do so could result
in poor connections and possible leaks.
CAUTION:
The lowest point of the line should
be the point of connection to the Drain Clamp.
There should be no sag in the line as this may
cause excessive noise as the reject water is
flowing to drain.
•Refer to Fig. 4. Insert the tubing into the Drain
Clamp. Make sure the tubing is pressed
all the way in to create a pressure-tight
connection.
NOTE: If you want to pull the tubing out for
some reason, push the ring around the tubing
in and pull the tubing out.
D. R.O. Manifold Assembly Installation
Locate the site per Sec. III, C.3. Various installation
sites will require different types of mounting
fasteners; be sure the fastener selected will
provide a firm, solid mounting. A support panel
may be necessary on thin cabinet walls or to span
between wall studs on particle board or drywall.
Do not drill through exterior cabinet walls or leave
sharp wood screw points exposed in readily
accessible cabinet interiors.
The close proximity of a dishwasher or a trash
compactor may require special fabrication of a
mounting plate.
1. The mounting bracket will accept either #10
or #12 (5mm) mounting screws spaced on
6" (15 cm) centers. Allow at least 4" (10 cm)
of clearance beneath the filter housings to
accommodate filter changes. Mark the two
locations (the bracket can be used as a
template). Install the screws and tighten them
until the heads are about
5
/
8
" from the wall.
RED
BLACK
YELLOW
IN
DRAIN
OUT
DRAIN
RESTRICT
OR
B
L
U
E
2. Locate the ¼" Red Feed Water Tubing.
Remove the red plug from the fitting labeled
“In” on the manifold and insert the tubing.
The fittings will grab the tubing and seal it in
place. Make sure the tubing is pressed all the
way in to create a pressure tight connection.
Reference the special supplement sheet in
the carton for proper connection of all tubing
and removal of plugs. Run the tubing along its
course to the Feed Water Saddle Valve, trim to
length. (Refer to Fig. 1, page 5.)
Refer to Fig. 3. To the end of the red polytube
install the Compression Nut, the Plastic
Ferrule, and the Brass Insert. Connect to the
Feed Water Saddle Valve.
3. Locate the ¼" Black Drain Tubing connected
to the Dispensing Faucet. The end of the Black
Drain Tubing that should be inserted into the
“Drain” port on the manifold will have a green
drain restrictor in it. Remove the black plug
from the fitting labeled “Drain” on the manifold
and insert the tubing. Allow the tubing to relax,
then press firmly again to insure proper seating.
4. Locate the 3/8" yellow tubing. Remove the
yellow plug from the fitting on top of the
manifold labeled "Tank" and insert the tubing.
(Refer to Fig. 1, page 5.)
5. Locate the 3/8" Blue Product Water Tubing
connected to the Dispensing Faucet. Remove
the blue plug from the elbow connected to the
fitting labeled “Out” on the manifold, trim the
tubing to length and insert the tubing. The fitting
will grab the tubing and seal it in place. Make
sure the tubing is pressed all the way in past
the o-ring to create a pressure tight connection.
NOTE:
If you want to pull the tubing out for
some reason, push the ring around the tubing
in and pull the tubing out.
6. Hang the Manifold Assembly on the mounting
screws and tighten. DO NOT OVERTIGHTEN.