Drain Connection Instalaltion (Figure 4)

Faucet Installation (Figure 5)

How to Use “Push In” Connectors (Figure 6)

How to Use “Push In” Connectors

This product is equipped with user-friendly “Push In” connectors. Proper use of the connectors is shown in the diagrams. 
It is most important that the tubing selected for use with the connectors be of high quality, exact size and roundness, 
and with no surgace nicks or scratches. If it is necessary to cut the tubing, use a plastic tubing cutter or sharp razor 
knife. Make a clean square cut. Should a leak occur at a Push In connector, the cause is usually defective tubing.

To fix:   1. Relieve pressure.  

2. Release tubing.  

3. Cut off at least 1/4” from end.  

 

4. Reattach tubing. 

5. Confirm connection is leak-free.

Garbage
Disposal

NEVER

 mount here

Mount drain saddle at

either location

Hole should be

located on top

of the pipe

Drain saddle elbow

Drain saddles

Drain Connection

(horizontal example)

C.L.

Base plate

Rubber washer

Slotted washer

Spacer

Threaded nipple

Hex nut

3/8" Tubing from storage tank

Air gap hole

1/4" Standard green tubing

Special red "SFC"
tubing from RO

Black 3/8" Reject tubing to drain

Blue 1/4" Product water tubing

Back View

Side View

Flat washer

Blue 1/4” Product
water tubing

1

2

Grey Collet 

Tube

1

2

 

g

n

i

b

u

T

 

e

s

a

e

l

e

R

 

o

T

 

g

n

i

b

u

T

 

h

c

a

tt

A

 

o

T

Push tubing straight in as far as it will go.  Tubing must be inserted past o-ring and

hit backstop.  Pull tube to ensure it is secured.

Push in grey collet to release tubing.  With collet held, pull tubing straight out.

To reduce the risk associated with property damage due to water leakage:
  • 

Ensure all tubing and fittings are secure and free of leaks.

  • 

Do not install unit if collet is missing.  Contact CUNO if collets are missing from any fittings.

CAUTION

NOTES: 

17

Содержание AP-R05500

Страница 1: ...intenance Instructions For Aqua Pure AP RO5500 Reverse Osmosis Drinking Water Filtration System Installer Please leave manual with homeowner Homeowner Please retain for operation and future maintenanc...

Страница 2: ...uring the installation of this product To reduce the risk associated with eye skin and respiratory and digestive tract burns from Calcium Hypochlorite during installation Calcium Hypochlorite CAS 7778...

Страница 3: ...sachusetts Michi gan Minnesota New Hampshire North Dakota Ohio Oregan and South Dakota Check your local plumb ing codes for any restrictions that apply It is mandatory that safety glasses be worn duri...

Страница 4: ...e with flexible ribbed supply tubing or plastic pipe which require special hardware Soft Copper Tubing Installations A Turn off cold water valve under the sink or the main water supply valve for the h...

Страница 5: ...ired to seal the sprayer connection on the existing faucet Before starting the undercounter installation procedure inspect the condition of the drain piping especially in older homes where the traps a...

Страница 6: ...abinet sidewall taking into consideration the space available and the tank location Generally the tank is placed in the rear of the sink cabinet while the purification assembly is positioned toward th...

Страница 7: ...ning wait and drain tank the following day Only when the tank is full should an icemaker be turned on if one is connected to the system NOTE When the system is first turned on water may intermittently...

Страница 8: ...is still displayed the membrane should be replaced Recommended service life of the RO membrane is 36 months maximum To reduce the risk associated with property damage due to water leakage The disposab...

Страница 9: ...ical as possible 3 8 Yellow For best flow keep tubing from Tank to RO Assembly as short as possible Faucet without Air Gap Cold Water Supply Only Storage Tank Sink Drain Red SFC Tubing 3 8 Yellow 1 4...

Страница 10: ...e Garbage Disposal NEVER mount here Mount drain saddle at either location Hole should be located on top of the pipe Drain saddle elbow Drain saddles Drain Connection horizontal example C L Base plate...

Страница 11: ...uct that is actually defective malfunctioning or otherwise in violation of this warranty If CUNO for any reason cannot repair a Product covered hereby within two 2 weeks after receipt of the original...

Отзывы: