Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Long Term Non-Use

If the RO filtration system is left unused for long periods (>30 days), follow this procedure:
A) Open faucet to drain tank and turn off feedwater valve. Wait five minutes for RO assembly to depressurize.
B) Remove all cartridges. Turn cartridges upside down in sink or container to drain out as much water as 

possible.

C) Place cartridges in a plastic bag with air tight seal and store in refrigerator. Cartridges must not be al-

lowed to freeze or permanent damabe may occur.

D) When RO filtration system is ready to be put into service, reinstall cartridges in the RO assembly 

heads and sanitize storage tank as described in Section 4. The RO assembly can also be sanitized at 
this time, if desired.

E) Follow start up procedure outlined in Section 4.

18.  Parts List

Item No.

Description

Part No.

1

RO Module

56084-01

2

Replacement Cartridges

55981-01

3

Shut Off Valve

60-90119

4

SFC Tubing

52-318212

2

4

1

3

AP5500 Line Art

14

15

General Undercounter Installation Schematic (Figure 1)

General Basement Installation Schematic (Figure 2)

Feedwater Valve Installation (Figure 3)

Faucet with
Air Gap

Cold Water
Supply Only

Storage

Tank

Sink

Drain

Red SFC Tubing

3/8” Black

3/8” Yellow

3/8” Blue

RO

Assembly

1/4” Orange

1/4” Green

For best flow, tubing must
be as vertical as possible.

3/8” Yellow

For best flow, keep 
tubing from Tank 
to RO Assembly as 
short as possible.

Faucet without
Air Gap

Cold Water

Supply Only

Storage Tank

Sink
Drain

Red SFC Tubing

3/8” Yellow

1/4” Green

3/8” Blue

RO

Assembly

1/4” Orange

Air gap device
(eg. Gap-A-Flow)

To laundry sink
standpipe or floor
drain

Floor

Undersink Area

For best flow, keep 
tubing from Tank 
to RO Assembly as 
short as possible.

Faucet with
Air Gap

Cold Water
Supply Only

Storage

Tank

Sink

Drain

Red SFC Tubing

3/8” Black

3/8” Yellow

3/8” Blue

RO

Assembly

1/4” Orange

1/4” Green

For best flow, tubing must
be as vertical as possible.

3/8” Yellow

For best flow, keep 
tubing from Tank 
to RO Assembly as 
short as possible.

Faucet without
Air Gap

Cold Water

Supply Only

Storage Tank

Sink
Drain

Red SFC Tubing

3/8” Yellow

1/4” Green

3/8” Blue

RO

Assembly

1/4” Orange

Air gap device
(eg. Gap-A-Flow)

To laundry sink
standpipe or floor
drain

Floor

Undersink Area

For best flow, keep 
tubing from Tank 
to RO Assembly as 
short as possible.

For 3/8” OD tubing use side of
bracket with projections

For 7/16” - 1/2” OD tubing or rigid
pipe use “V” side of bracket

nut/seal

piercing
lance

insert

plastic sleeve

compression nut

1/4” orange
feed water
tubing

IMPORTANT NOTES

  

  • Some  state  and  local  plumbing  codes  may 

prohibit the use of saddle-type valves and/or 
drain  connections.    The  use  of  saddle-type 
valves  are  prohibited  in:  Alaska,  Delaware, 
Idaho,  Kentucky,  Massachusetts,  Michigan, 
Minnesota,  New  Hampshire,  North  Dakota, 
Ohio,  Oregan  and  South  Dakota.    Check 
your local plumbing codes for any restrictions 
that apply.

Содержание AP-R05500

Страница 1: ...intenance Instructions For Aqua Pure AP RO5500 Reverse Osmosis Drinking Water Filtration System Installer Please leave manual with homeowner Homeowner Please retain for operation and future maintenanc...

Страница 2: ...uring the installation of this product To reduce the risk associated with eye skin and respiratory and digestive tract burns from Calcium Hypochlorite during installation Calcium Hypochlorite CAS 7778...

Страница 3: ...sachusetts Michi gan Minnesota New Hampshire North Dakota Ohio Oregan and South Dakota Check your local plumb ing codes for any restrictions that apply It is mandatory that safety glasses be worn duri...

Страница 4: ...e with flexible ribbed supply tubing or plastic pipe which require special hardware Soft Copper Tubing Installations A Turn off cold water valve under the sink or the main water supply valve for the h...

Страница 5: ...ired to seal the sprayer connection on the existing faucet Before starting the undercounter installation procedure inspect the condition of the drain piping especially in older homes where the traps a...

Страница 6: ...abinet sidewall taking into consideration the space available and the tank location Generally the tank is placed in the rear of the sink cabinet while the purification assembly is positioned toward th...

Страница 7: ...ning wait and drain tank the following day Only when the tank is full should an icemaker be turned on if one is connected to the system NOTE When the system is first turned on water may intermittently...

Страница 8: ...is still displayed the membrane should be replaced Recommended service life of the RO membrane is 36 months maximum To reduce the risk associated with property damage due to water leakage The disposab...

Страница 9: ...ical as possible 3 8 Yellow For best flow keep tubing from Tank to RO Assembly as short as possible Faucet without Air Gap Cold Water Supply Only Storage Tank Sink Drain Red SFC Tubing 3 8 Yellow 1 4...

Страница 10: ...e Garbage Disposal NEVER mount here Mount drain saddle at either location Hole should be located on top of the pipe Drain saddle elbow Drain saddles Drain Connection horizontal example C L Base plate...

Страница 11: ...uct that is actually defective malfunctioning or otherwise in violation of this warranty If CUNO for any reason cannot repair a Product covered hereby within two 2 weeks after receipt of the original...

Отзывы: