2 PIECE BODY BALL VALVES - FS660 SERIES
Australian Pipeline Valve - Installation, Operation and Maintenance Manual
12
11
10
9
7
6
5
8
15
12
NO DESCRIPTION
5
Gasket
6
Thrust Seal
7
Gland Packing
8
Stem
9
Gland Nut
10
Washer
11
Stem Nut
12
Lever
15
Anti-static Device
16
Stem O-ring*
*1 Depends on size & class
Sample only, design depends on size,
model & class. Refer to as-built drawing
FIG 2. CONSTRUCTION FOR GLAND PARTS
(non direct mount)
NO DESCRIPTION
5
Stem
6
Anti-static Device
8
Stem Seal
9
O-Ring
10
Stem Packing Set
11
Bushing
12
Gland
13
Belleville Washers
14
Stem Nut
15
Stop-Lock Cap
16
Handle Gland
17
Handle Nut
18
Lock Device
19
Handle
20
Handle Sleeve
21
Stop Bolt
Sample only, design depends on size,
model & class. Refer to as-built drawing
21
5
8
6
9
20
19
17
18
13
11
12
14
15
16
10
FIG 2a. CONSTRUCTION FOR GLAND PARTS
(direct mount)
4.2 BODY SEAL
Sealing between the threaded body is provided by a gasket (Teflon or graphite) and both valve segment
surfaces also provide metal to metal friction fit sealing. In larger sizes or higher pressures an elastomer
o-ring may also be used. In case of slight leakage check the threaded body joint is properly tightened up.
If a gasket seal is disturbed while removing or adjusting gasketed parts, APV
recommends installing a new gasket while reassembling. A proper seal is required
to ensure optimum operation.