APsystems ECU-3 V4 Installation/User Manual
10
ECU Initialization Sequence
Once power is supplied to the ECU, it automatically steps through
a series of initialization screens on its LCD display.
LCD Display
Figure 12
Step 1: Power on ECU
The following information will be displayed on LCD after ten seconds.
1) Loading the software firmware:
Figure 13
2) Waiting user to enter the inverter IDs on local web. Alternate
displaying 1 and 2 for every 5 seconds:
Lan IP Address
Display 1
Wireless IP Address
Display 2
Figure
14
A word about network communication protocols. The ECU needs
to have access to the router via a lan IP address. The ECU will only
search for and obtain a Dynamic Host Configuration Protocol (DHCP)
IP address during its powering up sequence.
For example, the LCD screen on the front of the ECU displays an lan
IP address such as “192.168.1.101” if the connection to the router is
successful (the IP address will vary based on router supplier, so check
with the user manual for specifics). If, however, the LCD displays
“192.168.131.228”, the ECU-router connection has not been successful,
in which case you’ll need to check all of the cabling connections and
reboot the ECU by removing the power cable for a few seconds and
reconnecting.