![Aprimatic SLIDE 230 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/aprimatic/slide-230/slide-230_electrical-installation-use-and-maintenance-instructions_2956730025.webp)
-
25
-
SLIDE 230 APRICODE
CONTROL UNIT
English
IMPORTANT:
BLUE
To select
RED
To con
fi
rm
YELLOW
To exit
parameter FUNCTION
..................................
DEFAULT
SETTINGS
LO
.
Logic ...........................................AUTOMATIC
0 =
AUTOMATIC
; 4
=
STEP
-
BY
-
STEP
;
1 =
FOUR
STEPS
; 5
=
MANNED
;
2 =
SUPER
AUTOMATIC
; 6
=
TIMER
(
START
INPUT
)
3 =
SEMI
AUTOMATIC
WITH
STOP
; 7
=
PARK
8 =
PARK
SPECIAL
PA
.
Pause time.....................................
25
sec.
0 ÷ 60 (1
SEC
.
STEPS
)
Cp
.
Weight class .............................
700
÷
1000
kg
0= 0÷100;
1= 100÷300;
2= 300÷700; 3=700÷1000;
4=
1000÷1300; 5=
1300÷1600; 6=
1600÷2000;
LAm
.
Pre-
fl
ashing time ...............................
3
sec.
1 ÷ 9 (1
SEC
.
STEPS
)
d1
.
Opening direction.................................
0
0 ; 1
moD
.
Operator type ........................... with Z16 pinion
0=
WITH
Z16
PINION
; 1=
WITH
Z20
PINION
e1
.
Wing power (FULL stroke) .................MAX
THRUST
FORCE
ELECTRONIC
ADJUSTMENT
: 0 (
MINIMUM
) ÷ 99 (
MAX
)
e2
.
Wing power (SLOW stroke) ...............MAX
THRUST
FORCE
ELECTRONIC
ADJUSTMENT
: 0 (
MINIMUM
) ÷ 50 (
MAX
)
rp
.
Pre limit switch slowing ...................
200
mm.
0 ÷ 8 (0 ÷ 800
MM
- 100
MM
STEPS
)
ra
.
Post limit switch slowing ....................
0
sec.
0 ÷ 20 (0 ÷ 2
SEC
- 100
MSEC
.
STEPS
)
rH
.
Final braking (hard) ........................ DISABLED
0 ÷ 20 (0 ÷ 2
SEC
- 100
MSEC
.
STEPS
)
PSET
.
Restore factory settings (default)
RED
TO
CONFIRM
(
def
FLASHING
L0
. =
CONCLUDED
)
man
.
Access MAINTENANCE menu
RED
TO
CONFIRM
RadI
Access MEMORIES menu
RED
TO
CONFIRM
Prof
Access ADVANCED programming
RED
TO
CONFIRM
A3
Pedestrian opening ...............................30%
1 ÷ 9 (10%
STEPS
)
A7
Maximum torque time during startup ...
0
,
5
sec.
1 ÷ 5 (0.5-
SECOND
STEPS
)
A8
Reverse time at end of motion ...........
0
sec.
0 ÷ 5 (
A
STEP
DI
20
MSEC
.)
LUM
.
Display luminosity .............................. MEDIUM
0 ÷ 9
Ad
Closing when photocell
uncovered ..............................
reloads pause time
00=
IMMEDIATELY
; 01=
AT
THE
END
OF
PAUSE
TIME
(
COUNTING
CONTINUES
) ;
02=
AFTER
10
SEC
. ; 03=
AFTER
A
NEW
COMPLETE
PAUSE
TIME
(
RELOADS
THE
PAUSE
TIME
)
Ae
Auxiliary output ........................... WARNING LIGHT
0 =
WARNING
LIGHT
; 1÷60 =
MINUTES
COURTESY
LIGHT
ON
AFTER
START
OR
PEDESTRIAN
START
NOTE
: only if not set on remote control
AH
.
Flashing light during pause ...................OFF
0=
OFF
; 1=
ON
(
IN
AUTOMATIC
MODE
)
Ar
.
Aux. opening safety device .............PHOTOCELL
0=
SAFETY
EDGE
; 1=
PHOTOCELL
tf
.
Closing photocell test .....................DISABLED
0 =
DISABLED
; 1 =
STANDARD
FOTOCELL
TEST
; 2 =
REFLEX
FOTOCELL
TEST
An
.
Aux. opening safety device test ....DISABLED
0 =
DISABLED
; 1 =
STANDARD
PHOTOCELL
OR
EDGE
TEST
; 2=
REFLEX
PHOTOCELL
OR
EDGE
TEST
eC
.
0
- Do NOT modify
DO
NOT
MODIFY
Ms
.
Master/Slave function.....................DISABLED
0=
DISABLED
; 1=
MASTER
; 2=
SLAVE
;
OPEN
Saving the remote controls on the
built-in receiver Apricode ...........
open the memory
RED
TO
CONFIRM
(
THE
DISPLAY
SHOWS
seed
FOR
15
SEC
.)
rn
.
Deleting a remote control with address
0 ÷ 99
(
SEE
PROGRAMMING
REMOTE
CONTROLS
)
r
.
tr
Deleting all remote controls
RED
TO
CONFIRM
UPLd
Saving control unit data on Plug-in memory module
RED
TO
CONFIRM
- (
OPTIONAL
PLUG
-
IN
MEMORY
MODULE
)
dnLd
Saving data from Plug-in memory module on control unit
RED
TO
CONFIRM
- (
OPTIONAL
PLUG
-
IN
MEMORY
MODULE
)
ch1
ch2
ch3
ch4
Remote control Output channel
ch1
................................................. START
ch2
......................................PEDESTRIAN START
ch3
;
ch4
.........................................
DISABLED
0 =
DISABLED
; 1
=
START
; 2
=
PEDESTRIAN
START
; 3 =
STOP
;
4 =
AUXILIARY
OUTPUT
USING
EXTERNAL
RELAIS
(2 sec. pulse if
Ae
=
0
;
timer
1÷60
if
Ae
=
1÷60
sec.)
AL
.
t
Movement Total counter - cannot be tampered
0000 ÷ 9999 (
INCREASES
BY
1
FOR
EVERY
100
MOVEMENTS
)
AL
.
P
Movement Partial counter for maintenance
0000 ÷ 9999 (1 = 10
MOVEMENTS
) (
RESET
USING
AL
.
S
OR
AL
.
r
)
AL
.
S
Sets maintenance cycle on
AL
.
P
0000 ÷ 9999 (1 = 10
MOVEMENTS
)
WITH
MINIMUM
STEP
100
MOVEMENTS
-
EACH
SETTING
ZERO
-
SETS
THE
COUNTER
AL
.
P
aL
.
r
Zero-sets the counter
AL
.
P
RED
TO
CONFIRM
Содержание SLIDE 230