![Aprimatic SLIDE 230 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/aprimatic/slide-230/slide-230_electrical-installation-use-and-maintenance-instructions_2956730024.webp)
-
24
-
English
SLIDE 230 APRICODE
CONTROL UNIT
ERROR CODES
noEE
•
= failed access to memory during the power up;
Init
•
= missing of data in memory
(press
YELLOW
and
BLUE
simultaneously for approx. 3 sec.
Lrn
fl
ashes on
display press START);
Er1
•
= failed access to the memory during UPLOAD/DOWNLOAD;
Er2
•
= closing photocell test;
Er3
•
= auxiliary photocell test;
Er9
•
= motor/limit switches
(verify the connection)
ErFc
•
= STOP due to a failure of the limit switches
MAn
•
(
fl
ashes for approximately 3 sec. when programming
is accessed)
=
routine maintenance is required
.
Inputs and outputs
4.2
•
START
(using button with N.O. contact or remote control)
- starts the automation (opening or closing) on the basis of
the current state and the operating logic settings.
•
STOP
(button with N.C. contact) - the input stops the
wing immediately. A
START pulse is required to continue
movement.
The STOP input has priority over all other
functions at all times.
•
Closing photocells
- these photocells are only enabled on
the closing stroke. When triggered they will stop the movement
for 1 sec. and then start to reopen the gate.
These photocells
will prevent closing as long as they are covered.
•
Auxiliary safety edge operating on opening stroke
-
this is a safety input enabled during the opening stroke. The
safety edge will trigger if it touches an obstacle during the
opening stroke. The wing will reverse for a short distance
and then stop. You must press START, the gate will close.
•
Auxiliary opening safety photocells
- these photocells
detect obstacles on the opening and closing strokes; they
will trigger on detecting an obstruction and stop the gate.
The movement will only restart when the photocells are
uncovered. After 1 sec. of pause, the movement will restart
in the original direction.
To signal the status of the automation:
•
Flashing light
/
•
Warning light (remote signal)
:
AUTOMATION
STATUS
FLASHING
LIGHT
WARNING
LIGHT
gate opening
fl
ashing (1 sec.)
light ON
gate closing
fl
ashing (1 sec.)
fl
ashing
gate open
light OFF (parameter
AH
) light ON
gate closed/stopped light OFF
light OFF
auxiliary safety
light ON
-
routine maintenance
fl
ashing (0.5 sec.)
-
•
Auxiliary output using external relay
depending on
(
ae
) parameter: 2 sec pulse type with activation by remote
control (
ch1
-
4
) (ex: pedestrian gate electric lock actuation)
OR timer (ex: lighting).
•
Courtesy light
- light ON when START or PEDESTRIAN
START is pressed, with programmable timer (
ae
).
Checks and warnings on display
4.3
To switch ON the display, press the
•
YELLOW
once quickly.
To switch OFF the display, press once quickly again.
PROGRAMMING THE PARAMETERS
5.
IMPORTANT! The gate must be stopped and closed before you can start programming.
WARNING: All input signals will be ignored during programming.
Press and hold
RED button
the display shows
PROC
Release the
RED button
displays the
fi
rst parameter with the value set
LO
.
0
BLUE
scrolls through the parameters
MODIFICA
TIONS to
SETTINGS
RED
when a parameter shown
shows the value set
(marked by the bullet)
pressing the
BLUE button
scrolls through the values
Press and hold the
RED
button for 3 seconds
to select a new value
3
fl
ashes con
fi
rm the modi
fi
cation
Release the
RED button
the new setting is displayed
YELLOW
returns to the parameters
The parameter has now been modi
fi
ed. More modi
fi
cations can be made before you exit the programming function.
WARNING:
modifi cations are only confi rmed when you exit the programming function (display switched OFF).
If the power supply fails for any reason during programming, all the modifi cations you have made will be lost.
To
EXIT
programming:
press the
YELLOW
button until the display is switched OFF
Parameters enabling RESET or operations involving MEMORIES: before the modifi cation is confi rmed the display shows
SURE
,
if confi rmation is given (RED button) fl ashes for 3 sec.
donE
(positive outcome) o
Er
+ error code in the event of failure.
Ö
8 8 8 8
1 2 3 4
YELLOW
display 1
: GATE STATUS
C
= CLOSED
b
= OPENING
A
= OPEN
d
= CLOSING
E
= LOCKED
0
= OBSTACLE detection
8
2
4
5
6
7
display 2
: INPUTS (ON=contact closed)
1 = START radio
2 = CLOSING PHOTOCELL
4 = PEDESTRIAN START
5 = SAFETY DEVICE during OPENING
6 = START
7 = STOP
8
1
3
display 4
: OUTPUTS
(ON=output active)
1 = FLASHING LIGHT
3 = WARNING LIGHT
display 3
: LIMIT SWITCHES
(OFF=the limit switch is triggered)
1 = OPENING limit switch
6 = CLOSING limit switch
8
1
6
Checks and warnings on display
fi g. 6 -
Содержание SLIDE 230