ELECTRICAL SYSTEM
6
- 19
RSV mille
6.6.2 STARTING SAFETY OPERATING LOGIC
NOTE
With the engine shutoff switch in position “
m
” the
starter motor does not turn over.
6.6.3 CHECKING THE STARTING RELAY
To check operation of the relay:
◆
Remove the rider’s saddle, see 7.1.1 (REMOVING
◆
Disconnect the two-way connector (1) (coloured white).
a
CAUTION
When reassembling, make sure the electric connec-
tor (1) is plugged in properly.
◆
Lift the relay and slip it off the relevant couplings (2).
◆
Slip off the two rubber protections (3-4).
◆
Disconnect the cables (5-6) from the relevant terminals
on the relay (2).
◆
From the relay side, power the two internal terminals of
connector (1) at 12V.
◆
Using a tester (acting as ohmmeter), check the for
breaks between the two screw contacts on the relay
(2).
Correct value with relay powered: 0
Ω.
Correct value with relay not powered:
∞
Ω.
If the values do not correspond to those indicated,
change the relay (2).
GEAR POSITION
STAND POSITION
CLUTCH LEVER
STAND
WARNING LIGHT
ENGINE IGNITION
STARTER MOTOR
IN NEUTRAL
LIFTED
PULLED UP
OFF
WORKING
TURNING OVER
RELEASED
LOWERED
PULLED UP
ON
RELEASED
GEAR ENGAGED
LIFTED
PULLED UP
OFF
RELEASED
NOT TURNING OVER
LOWERED
PULLED UP
ON
NOT WORKING
RELEASED
Содержание 8140172
Страница 1: ...RSV mille MIN 956X Service and repair manual aprilia part 8140172 ...
Страница 5: ...0 4 RSV mille NOTE ...
Страница 6: ...1 1 RSV mille GENERAL INFORMATION 1 ...
Страница 28: ...2 1 RSV mille 1 SERVICE AND SETTING UP 2 ...
Страница 84: ...3 1 RSV mille 1 3 ENGINE 3 ...
Страница 200: ...4 1 RSV mille 1 2 3 FUEL SUPPLY SYSTEM 4 ...
Страница 226: ...5 1 RSV mille 1 2 3 4 COOLING SYSTEM 5 ...
Страница 236: ...6 1 RSV mille 6 6 6 6 6 ELECTRICAL SYSTEM 6 ...
Страница 239: ...6 4 ELECTRICAL SYSTEM RSV mille 42 0 43 9 54 ...
Страница 279: ...6 44 ELECTRICAL SYSTEM RSV mille NOTE ...