Installation and Service Manual – Carbon Filter
Page 10
Copyright © 2012 Applied Membranes, Inc. All Rights Reserved.
Regeneration Screens
During Regeneration: The display shows the time remaining in the current cycle.
Pressing “REGEN” will advance to the next cycle.
Set Time of Day
In the event of a prolonged power
outage, time of day flashes,
indicating that it needs to be
reset. All other information will be
stored in memory no matter how
long the power outage. Please
complete the steps as shown to
the right.
(Time of day will only need to be set
when a power outage lasts more than
8 hours, or when daylight savings
time begins or ends.)
Press NEXT until the time of day screen is
displayed.
Press and hold
▲
or
▼
until the SET indicator is
displayed and the hour flashes.
Press
▲
or
▼
until the correct hour is displayed.
Press NEXT, the minutes will flash.
Press
▲
or
▼
until the correct minute is
displayed.
Press NEXT to return to the display screen.
Button Operation and Function
Scrolls to the Next Display
Press once and release to schedule a regeneration at the preset delayed regeneration
time. (Press and release again to cancel the regeneration.)
Press and Hold for 3 seconds to initiate an immediate regeneration.
While Regeneration is in Process:
Press to advance to the next cycle.
While in Programming Screens:
Press to go backwards to the previous screen.
Changes variable being displayed.
Key sequence to lock and unlock program settings.
Press and Hold for 3 seconds to initiate a control reset. The software version is displayed
and the piston returns to the home/service position, resynchronizing the valve.
Error Message
If the word “ERROR” and a number are alternately flashing on the display, check the
trouble shooting section of this manual to identify the error. Clear error by disconnecting
the power supply at the PC board and reconnecting, or press the NEXT and REGEN
buttons simultaneously for 3 seconds.
User Display
When in normal operation, one of two displays may be
shown. Pressing NEXT will alternate between the displays.
User Screen 1:
Displays number of days until next
scheduled regeneration.
User Screen 2:
Shows current time.
Manual Regeneration
Delayed Regeneration:
Press and Release the “REGEN” button.
“
◄
” will flash towards REGEN. Regeneration will be performed “tonight” at the preset
time of day. (Cancel request by pressing the “REGEN” button again.)
Immediate Regeneration:
Press and Hold the “REGEN” button for approximately 3