Unit installation
1.
Adjust the locking mechanism on Stratus ESG using a 3/32 hex wrench so that
the front lobe is in a vertical position. Insert the unit into the mounting rack until
the faceplate is flush with the front end of the rack.
2.
Tighten the locking mechanism clockwise with the 3/32 hex wrench until it is tight
and the connectors have mated. Do not overtighten. If the mechanism will not
tighten, verify that Stratus ESG is properly seated in the rack.
2.5.
Cleaning
Use a dry cloth to clean Stratus ESG. If necessary, you can use a lightly damp cloth with a
solution of mild detergent. Do not use cleaners containing ammonia, acetone, or other strong
acids or bases to clean the Stratus ESG display or faceplate.
2.6.
Circuit protective device marking
If Stratus ESG is replacing an existing transponder, ensure that it is sufficiently marked.
If Status ESG is a new installation, ensure that the labeling is in accordance with AC 43.13-2B,
Chapter 2, Section 207, Sub-Section f., Paragraph (4).
3. Cabling and wiring
This section describes cabling and wiring specifications, pin-out information, and antenna
connection procedures.
CAUTION
: Stratus ESG must be OFF during wiring to avoid damaging the device.
3.1.
Cabling and wiring specifications
Wiring must be installed in accordance with FAA AC 43.13-1B and AC 43.13-2B and will be
supplied by the aircraft installer. Wiring will be 20-24 gauge; see Stratus ESG Installation and