CERTIFICATE OF COMPLIANCE 

EU Declaration of Conformity 

This declaration of conformity is issued under the sole responsibility of the manufacturer: 

 

Apogee Instruments, Inc. 
721 W 1800 N 
Logan, Utah 84321 
USA 

for the following product(s): 
 
Models: SQ-627 
Type: Extended Range PFD Sensor 
 
The object of the declaration described above is in conformity with the relevant Union harmonization legislation: 
 
2014/30/EU 

Electromagnetic Compatibility (EMC) Directive 

2011/65/EU 

Restriction of Hazardous Substances (RoHS 2) Directive 

2015/863/EU 

Amending Annex II to Directive 2011/65/EU (RoHS 3) 

 
Standards referenced during compliance assessment: 
 
EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use 

 EMC requirements 

EN 50581:2012  Technical documentation for the assessment of electrical and electronic products with respect to 

the restriction of hazardous substances 

 
Please be advised that based on the information available to us from our raw material suppliers, the products 
manufactured by us do not contain, as intentional additives, any of the restricted materials including lead (see 
note below), mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB), polybrominated 
diphenyls (PBDE), bis(2-ethylhexyl) phthalate (DEHP), butyl benzyl phthalate (BBP), dibutyl phthalate (DBP), and 
diisobutyl phthalate (DIBP). However, please note that articles containing greater than 0.1% lead concentration are 
RoHS 3 compliant using exemption 6c. 
 
Further note that Apogee Instruments does not specifically run any analysis on our raw materials or end products 
for the presence of these substances, but rely on the information provided to us by our material suppliers. 
 
Signed for and on behalf of: 
Apogee Instruments, April 2020 
 

 

Bruce Bugbee 
President 
Apogee Instruments, Inc. 

 

Содержание SQ-627

Страница 1: ...INC 721 WEST 1800 NORTH LOGAN UTAH 84321 USA TEL 435 792 4700 FAX 435 787 8268 WEB APOGEEINSTRUMENTS COM Copyright 2020 Apogee Instruments Inc OWNER S MANUAL EXTENDED RANGE PFD SENSOR Model SQ 627 in...

Страница 2: ...of Compliance 3 Introduction 4 Sensor Models 5 Specifications 5 Deployment and Installation 8 Cable Connectors 8 Operation and Measurement 10 Maintenance and Recalibration 14 Troubleshooting and Cust...

Страница 3: ...of electrical and electronic products with respect to the restriction of hazardous substances Please be advised that based on the information available to us from our raw material suppliers the produc...

Страница 4: ...quantum sensors but measure a wider range of wavelengths can be thought of as an extended range quantum sensor Typical applications of traditional quantum sensors include incoming PPFD measurement ov...

Страница 5: ...respective manuals Model Signal SQ 620 Self powered SQ 622 0 2 5 V SQ 624 4 20 mA SQ 625 0 5 V SQ 626 USB SQ 627 SDI 12 SQ 628 Modbus Sensor model number and serial number are located on the bottom o...

Страница 6: ...onse Time 0 6 s time for detector signal to reach 95 following a step change fastest data transmission rate for SDI 12 circuitry is 1 s Field of View 180 Spectral Range 340 to 1040 nm 5 nm wavelengths...

Страница 7: ...respectively Mean spectral response measurements of six replicate Apogee SQ 600 series Extended Range PFD Sensors Spectral response measurements were made at 10 nm increments across a wavelength range...

Страница 8: ...nted with the cable pointing toward true north in the northern hemisphere or true south in the southern hemisphere Azimuth error is typically less than 0 5 but it is easy to minimize by proper cable o...

Страница 9: ...please contact Apogee directly to ensure ordering the proper pigtail configuration Alignment When reconnecting a sensor arrows on the connector jacket and an aligning notch ensure proper orientation D...

Страница 10: ...tion php version 1 4 August 10 2016 Overview During normal communication the data recorder sends a packet of data to the sensor that consists of an address and a command Then the sensor sends a respon...

Страница 11: ...ommand signals a measurement sequence to be performed Data values generated in response to this command are stored in the sensor s buffer for subsequent collection using D commands Data will be retain...

Страница 12: ...ees if pointed down Available in sensors with serial number 3033 or greater aCC or aCC0 a00101 cr lf Returns mol m 2 s 1 w CRC aCC1 a00101 cr lf Returns millivolt output w CRC aCC2 a00101 cr lf Return...

Страница 13: ...g the sensor version number and xx xx is serial number Running Average Command The running average command can be used to set or query the number of measurements that are averaged together before retu...

Страница 14: ...g may be necessary Dust or organic deposits are best removed using water or window cleaner and a soft cloth or cotton swab Salt deposits should be dissolved with vinegar and removed with a cloth or co...

Страница 15: ...ble Measurement Devices Dataloggers Controllers Meters Any datalogger or meter with SDI 12 functionality that includes the M or C command An example datalogger program for Campbell Scientific datalogg...

Страница 16: ...warranty items to our factory The warranty does not cover equipment that has been damaged due to the following conditions 1 Improper installation or abuse 2 Operation of the instrument outside of its...

Страница 17: ...eeinstruments com to discuss repair or replacement options OTHER TERMS The available remedy of defects under this warranty is for the repair or replacement of the original product and Apogee Instrumen...

Отзывы: