OPERATION AND MEASUREMENT 

The SQ-627 Extended Range PFD sensor has a SDI-12 output, where photosynthetically active radiation is returned 
in digital format. Measurement of SQ-627 Extended Range PFD sensors requires a measurement device with SDI-
12 functionality that includes the M or C command. 
 

Wiring

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Sensor Calibration 

All Apogee SDI-12 Extended Range PFD sensor models (SQ-600 series) have sensor-specific calibration coefficients 
determined during the custom calibration process. Coefficients are programmed into the microcontrollers at the 
factory. 

SDI-12 Interface 

The following is a brief explanation of the serial digital interface SDI-12 protocol instructions used in Apogee SQ-
627 Extended Range PFD sensors. For questions on the implementation of this protocol, please refer to the official 
version of the SDI-12 protocol

http://www.sdi-12.org/specification.php

 (version 1.4, August 10, 2016).

 

 

Overview 

  
During normal communication, the data recorder sends a packet of data to the sensor that consists of an address 
and a command. Then, the sensor sends a response. In the following descriptions, SDI-12 commands and 
responses are enclosed in quotes. The SDI-12 address and the command/response terminators are defined as 
follows: 
 

Sensors come from the factory wi

th the address of “0” for use in single sensor systems. Addresses “1 to 9” and 

“A to Z”, or “a to z”, can be used for additional sensors connected to the same SDI

-12 bus. 

 

“!” is the last character of a command instruction. In order to be compliant with SD

I-12 protocol, all commands 

must be terminated with a “!”. SDI

-12 language supports a variety of commands.  Supported commands for the 

Apogee Instruments SQ-627 Extended Range PFD 

sensors are listed in the following table (“a” is the sensor 

address. The fo

llowing ASCII Characters are valid addresses: “0

-

9” or “A

-

Z”).

 

White: Positive (signal from sensor) 

Red: Input Power  

Black: Ground (from sensor signal and output power) 

Clear: Shield/Ground 

Содержание SQ-627

Страница 1: ...INC 721 WEST 1800 NORTH LOGAN UTAH 84321 USA TEL 435 792 4700 FAX 435 787 8268 WEB APOGEEINSTRUMENTS COM Copyright 2020 Apogee Instruments Inc OWNER S MANUAL EXTENDED RANGE PFD SENSOR Model SQ 627 in...

Страница 2: ...of Compliance 3 Introduction 4 Sensor Models 5 Specifications 5 Deployment and Installation 8 Cable Connectors 8 Operation and Measurement 10 Maintenance and Recalibration 14 Troubleshooting and Cust...

Страница 3: ...of electrical and electronic products with respect to the restriction of hazardous substances Please be advised that based on the information available to us from our raw material suppliers the produc...

Страница 4: ...quantum sensors but measure a wider range of wavelengths can be thought of as an extended range quantum sensor Typical applications of traditional quantum sensors include incoming PPFD measurement ov...

Страница 5: ...respective manuals Model Signal SQ 620 Self powered SQ 622 0 2 5 V SQ 624 4 20 mA SQ 625 0 5 V SQ 626 USB SQ 627 SDI 12 SQ 628 Modbus Sensor model number and serial number are located on the bottom o...

Страница 6: ...onse Time 0 6 s time for detector signal to reach 95 following a step change fastest data transmission rate for SDI 12 circuitry is 1 s Field of View 180 Spectral Range 340 to 1040 nm 5 nm wavelengths...

Страница 7: ...respectively Mean spectral response measurements of six replicate Apogee SQ 600 series Extended Range PFD Sensors Spectral response measurements were made at 10 nm increments across a wavelength range...

Страница 8: ...nted with the cable pointing toward true north in the northern hemisphere or true south in the southern hemisphere Azimuth error is typically less than 0 5 but it is easy to minimize by proper cable o...

Страница 9: ...please contact Apogee directly to ensure ordering the proper pigtail configuration Alignment When reconnecting a sensor arrows on the connector jacket and an aligning notch ensure proper orientation D...

Страница 10: ...tion php version 1 4 August 10 2016 Overview During normal communication the data recorder sends a packet of data to the sensor that consists of an address and a command Then the sensor sends a respon...

Страница 11: ...ommand signals a measurement sequence to be performed Data values generated in response to this command are stored in the sensor s buffer for subsequent collection using D commands Data will be retain...

Страница 12: ...ees if pointed down Available in sensors with serial number 3033 or greater aCC or aCC0 a00101 cr lf Returns mol m 2 s 1 w CRC aCC1 a00101 cr lf Returns millivolt output w CRC aCC2 a00101 cr lf Return...

Страница 13: ...g the sensor version number and xx xx is serial number Running Average Command The running average command can be used to set or query the number of measurements that are averaged together before retu...

Страница 14: ...g may be necessary Dust or organic deposits are best removed using water or window cleaner and a soft cloth or cotton swab Salt deposits should be dissolved with vinegar and removed with a cloth or co...

Страница 15: ...ble Measurement Devices Dataloggers Controllers Meters Any datalogger or meter with SDI 12 functionality that includes the M or C command An example datalogger program for Campbell Scientific datalogg...

Страница 16: ...warranty items to our factory The warranty does not cover equipment that has been damaged due to the following conditions 1 Improper installation or abuse 2 Operation of the instrument outside of its...

Страница 17: ...eeinstruments com to discuss repair or replacement options OTHER TERMS The available remedy of defects under this warranty is for the repair or replacement of the original product and Apogee Instrumen...

Отзывы: