Apogee SQ-627 Скачать руководство пользователя страница 16

RETURN AND WARRANTY POLICY 

RETURN POLICY  

Apogee Instruments will accept returns within 30 days of purchase as long as the product is in new condition (to be 
determined by Apogee). Returns are subject to a 10 % restocking fee.  

WARRANTY POLICY  

What is Covered 

All products manufactured by Apogee Instruments are warranted to be free from defects in materials and craftsmanship 
for a period of four (4) years from the date of shipment from our factory. To be considered for warranty coverage an 
item must be evaluated either at our factory or by an authorized distributor. 

 

Products not manufactured by Apogee (spectroradiometers, chlorophyll content meters, EE08-SS probes) are covered 
for a period of one (1) year.  

What is Not Covered 

The customer is responsible for all costs associated with the removal, reinstallation, and shipping of suspected warranty 
items to our factory. 

 

The warranty does not cover equipment that has been damaged due to the following conditions:  

1. Improper installation or abuse. 

2. Operation of the instrument outside of its specified operating range.  

3. Natural occurrences such as lightning, fire, etc.  

4. Unauthorized modification. 

5. Improper or unauthorized repair. 

Please note that nominal accuracy drift is normal over time. Routine recalibration of sensors/meters is considered part of 
proper maintenance and is not covered under warranty.  

Who is Covered 

This warranty covers the original purchaser of the product or other party who may own it during the warranty period. 

 

What Apogee Will Do 

At no charge Apogee will: 

 

1. Either repair or replace (at our discretion) the item under warranty.  

2. Ship the item back to the customer by the carrier of our choice.  

Different or expedited shipping methods will be at the customer’s expense. 

 

How To Return An Item  

1. Please do not send any products back to Apogee Instruments until you have received a Return Merchandise 

Содержание SQ-627

Страница 1: ...INC 721 WEST 1800 NORTH LOGAN UTAH 84321 USA TEL 435 792 4700 FAX 435 787 8268 WEB APOGEEINSTRUMENTS COM Copyright 2020 Apogee Instruments Inc OWNER S MANUAL EXTENDED RANGE PFD SENSOR Model SQ 627 in...

Страница 2: ...of Compliance 3 Introduction 4 Sensor Models 5 Specifications 5 Deployment and Installation 8 Cable Connectors 8 Operation and Measurement 10 Maintenance and Recalibration 14 Troubleshooting and Cust...

Страница 3: ...of electrical and electronic products with respect to the restriction of hazardous substances Please be advised that based on the information available to us from our raw material suppliers the produc...

Страница 4: ...quantum sensors but measure a wider range of wavelengths can be thought of as an extended range quantum sensor Typical applications of traditional quantum sensors include incoming PPFD measurement ov...

Страница 5: ...respective manuals Model Signal SQ 620 Self powered SQ 622 0 2 5 V SQ 624 4 20 mA SQ 625 0 5 V SQ 626 USB SQ 627 SDI 12 SQ 628 Modbus Sensor model number and serial number are located on the bottom o...

Страница 6: ...onse Time 0 6 s time for detector signal to reach 95 following a step change fastest data transmission rate for SDI 12 circuitry is 1 s Field of View 180 Spectral Range 340 to 1040 nm 5 nm wavelengths...

Страница 7: ...respectively Mean spectral response measurements of six replicate Apogee SQ 600 series Extended Range PFD Sensors Spectral response measurements were made at 10 nm increments across a wavelength range...

Страница 8: ...nted with the cable pointing toward true north in the northern hemisphere or true south in the southern hemisphere Azimuth error is typically less than 0 5 but it is easy to minimize by proper cable o...

Страница 9: ...please contact Apogee directly to ensure ordering the proper pigtail configuration Alignment When reconnecting a sensor arrows on the connector jacket and an aligning notch ensure proper orientation D...

Страница 10: ...tion php version 1 4 August 10 2016 Overview During normal communication the data recorder sends a packet of data to the sensor that consists of an address and a command Then the sensor sends a respon...

Страница 11: ...ommand signals a measurement sequence to be performed Data values generated in response to this command are stored in the sensor s buffer for subsequent collection using D commands Data will be retain...

Страница 12: ...ees if pointed down Available in sensors with serial number 3033 or greater aCC or aCC0 a00101 cr lf Returns mol m 2 s 1 w CRC aCC1 a00101 cr lf Returns millivolt output w CRC aCC2 a00101 cr lf Return...

Страница 13: ...g the sensor version number and xx xx is serial number Running Average Command The running average command can be used to set or query the number of measurements that are averaged together before retu...

Страница 14: ...g may be necessary Dust or organic deposits are best removed using water or window cleaner and a soft cloth or cotton swab Salt deposits should be dissolved with vinegar and removed with a cloth or co...

Страница 15: ...ble Measurement Devices Dataloggers Controllers Meters Any datalogger or meter with SDI 12 functionality that includes the M or C command An example datalogger program for Campbell Scientific datalogg...

Страница 16: ...warranty items to our factory The warranty does not cover equipment that has been damaged due to the following conditions 1 Improper installation or abuse 2 Operation of the instrument outside of its...

Страница 17: ...eeinstruments com to discuss repair or replacement options OTHER TERMS The available remedy of defects under this warranty is for the repair or replacement of the original product and Apogee Instrumen...

Отзывы: