background image

LOCAL BLOCK 

PRESET HANDLING BLOCK  

5

1.0 INTRODUCTION

Channel Select

Chooses one of
eight channels
from the
currently select-
ed unit.

Channel Status Readout

Displays input and output
gains settings, headroom,
and function status.

Multiple Select

Allows simultaneous
control of a group of
channels. When this
function is activated,
any channel selected
becomes part of the
group.

Mute

Shut down the analog output of
the selected channel. All func-
tions can be adjusted while a
channel is muted. This does not
effect digital output on Model
1788.

P48V

Engages the 48V phantom
power for condensor micro-
phones.

26dB PAD

Inserts a 26dB PAD (attenua-
tion) on the input stage.

Gain Control

Adjusts gain
setting for
selected
function;
Input, Main
Output and
Aux Output.

Gain Select

Determines the function of the
GAIN control; Input, Main
Output or Aux Output.

Polarity Reverse

Reverses polarity on
the input stage.

Enable Limiter

Engages the propri-
etary MicLm™
limiter. 

Low Cut 75Hz

Engages a
12dB/octave low cut
filter with a corner
frequency of 75Hz.

Load

Loads preset displayed
in NEXT readout. This
initiates a download of
all current settings from
connected Model 1788s
(except in Preset Edit
Mode).

Select

Selects the next
preset to be edited
or loaded. Selected
preset is displayed
in NEXT readout.

Preset Edit Mode

When activated, presets
can be edited without
transmitting control
data to the connected
Model 1788s.

Snap Shot

Used to take a snapshot
of the current settings
from all connected units.
This operation saves
settings into the preset
number that is shown in
the NEXT readout.

Erase

Erases preset
settings, turning
the selected preset
that is displayed in
NEXT readout into
an empty preset.

Protect/Unprotect

Toggling this switch protects
and unprotects presets. A
protected preset can not be
overwritten or erased. 

Preset Readout

The CURRENT
display shows the
preset that is in use.
The NEXT display
shows the next
preset to be loaded. 

Status LEDs

Shows status of preset in the
NEXT display; Mismatch,
Empty or Protected.

TEST TONE BLOCK

700 Hz Test Tone

Used to adjust system levels. One of two test
tone levels may be used. (0dBfs or -20 dBfs).

Содержание 1788-R

Страница 1: ...USER S GUIDE R E M O T E C O N T R O L L E R R FOR USE WITH THE MODEL 1788 8 CHANNEL MICROPHONE PREAMPLIFIER...

Страница 2: ...ms LTD All rights reserved All Aphex products are trademarks or registered trademarks of Aphex Systems LTD Other brand and prod uct names are trademarks or registered trademarks of their respective ho...

Страница 3: ...a Glance 4 1 3 Quick Setup 6 2 0 FUNCTIONS 2 1 Overview 8 2 2 Selection and Validation Block 8 2 3 Preset Handling Block 9 2 4 Secondary Functions 3 0 INTERFACING 3 1 Interfacing 12 3 2 When Using the...

Страница 4: ...manual covers only those features functions and interfacing configurations that are specific to the 1788 R 1 2 THE MODEL 1788 R REMOTE CONTROLLER AT A GLANCE This section is meant to serve as a quick...

Страница 5: ...Engages a 12dB octave low cut filter with a corner frequency of 75Hz Load Loads preset displayed in NEXT readout This initiates a download of all current settings from connected Model 1788s except in...

Страница 6: ...22 For long communication distance 100 feet 33 meters always use the RS 422 communication link For shorter distances choose between RS 232 and RS 422 based on availability of the proper communi cation...

Страница 7: ...ation green of the VALID LED for all connected units and the COMM TEST button will no longer be lit The COMM TEST button will flash during test procedure At the end of comm test unit 1 is selected as...

Страница 8: ...the communication status of all units identified under the communication test A solid green light means valid communication solid red light means invalid communication Under normal operation the VALID...

Страница 9: ...SELECT knob the three LEDs next to the readout indicate the preset s status as follows MISMATCH when the number of units in the selected presets do not match the number of units detected in the comm...

Страница 10: ...ou want to modify 5 To save the new settings select the Next preset number using SELECT knob in which the changes will be saved and press the SNAP SHOT button If the selected preset is protected first...

Страница 11: ...te ONLY in the Selection and Validation Block By selecting the unit with the UNIT SELECT button while the CLIP LIM LED is illuminated the memo ry time is reset and the Local Block now indicates using...

Страница 12: ...gnificant different in the noise immunity between the two connections The following table supplies the key differences of the two connectors Refer to Section 3 8 Communication Ports in the Model 1788...

Страница 13: ...it can be useful to use the 1788 Remote Program alongside the 1788 R due to certain advantages it offers For instance each Model 1788 in the system as well as all of their individual channels can be g...

Страница 14: ...non sequential order they will be loaded into the 1788 R sequentially It is possible for the same preset to be applied to different scenes which means the same preset can be downloaded to several pres...

Страница 15: ...nder the terms of the warranty you must also include proof of purchase Insure your shipment and send it to Aphex Systems Ltd ATTN RA enter RA here 11068 Randall Street Sun Valley CA 91352 PH 818 767 2...

Страница 16: ...ex Systems Ltd 11068 Randall Street Sun Valley CA 91352 PH 818 767 2929 FAX 818 767 2641 Copyright 1999 by Aphex Systems LTD All rights reserved All Aphex products are trademarks or registered tradema...

Отзывы: