background image

USER’S GUIDE

R E M O T E   C O N T R O L L E R

-

R

FOR  USE WITH 

THE MODEL 1788 8-CHANNEL

MICROPHONE PREAMPLIFIER

Содержание 1788-R

Страница 1: ...USER S GUIDE R E M O T E C O N T R O L L E R R FOR USE WITH THE MODEL 1788 8 CHANNEL MICROPHONE PREAMPLIFIER...

Страница 2: ...ms LTD All rights reserved All Aphex products are trademarks or registered trademarks of Aphex Systems LTD Other brand and prod uct names are trademarks or registered trademarks of their respective ho...

Страница 3: ...a Glance 4 1 3 Quick Setup 6 2 0 FUNCTIONS 2 1 Overview 8 2 2 Selection and Validation Block 8 2 3 Preset Handling Block 9 2 4 Secondary Functions 3 0 INTERFACING 3 1 Interfacing 12 3 2 When Using the...

Страница 4: ...manual covers only those features functions and interfacing configurations that are specific to the 1788 R 1 2 THE MODEL 1788 R REMOTE CONTROLLER AT A GLANCE This section is meant to serve as a quick...

Страница 5: ...Engages a 12dB octave low cut filter with a corner frequency of 75Hz Load Loads preset displayed in NEXT readout This initiates a download of all current settings from connected Model 1788s except in...

Страница 6: ...22 For long communication distance 100 feet 33 meters always use the RS 422 communication link For shorter distances choose between RS 232 and RS 422 based on availability of the proper communi cation...

Страница 7: ...ation green of the VALID LED for all connected units and the COMM TEST button will no longer be lit The COMM TEST button will flash during test procedure At the end of comm test unit 1 is selected as...

Страница 8: ...the communication status of all units identified under the communication test A solid green light means valid communication solid red light means invalid communication Under normal operation the VALID...

Страница 9: ...SELECT knob the three LEDs next to the readout indicate the preset s status as follows MISMATCH when the number of units in the selected presets do not match the number of units detected in the comm...

Страница 10: ...ou want to modify 5 To save the new settings select the Next preset number using SELECT knob in which the changes will be saved and press the SNAP SHOT button If the selected preset is protected first...

Страница 11: ...te ONLY in the Selection and Validation Block By selecting the unit with the UNIT SELECT button while the CLIP LIM LED is illuminated the memo ry time is reset and the Local Block now indicates using...

Страница 12: ...gnificant different in the noise immunity between the two connections The following table supplies the key differences of the two connectors Refer to Section 3 8 Communication Ports in the Model 1788...

Страница 13: ...it can be useful to use the 1788 Remote Program alongside the 1788 R due to certain advantages it offers For instance each Model 1788 in the system as well as all of their individual channels can be g...

Страница 14: ...non sequential order they will be loaded into the 1788 R sequentially It is possible for the same preset to be applied to different scenes which means the same preset can be downloaded to several pres...

Страница 15: ...nder the terms of the warranty you must also include proof of purchase Insure your shipment and send it to Aphex Systems Ltd ATTN RA enter RA here 11068 Randall Street Sun Valley CA 91352 PH 818 767 2...

Страница 16: ...ex Systems Ltd 11068 Randall Street Sun Valley CA 91352 PH 818 767 2929 FAX 818 767 2641 Copyright 1999 by Aphex Systems LTD All rights reserved All Aphex products are trademarks or registered tradema...