2.0  FUNCTIONS

2.1   OVERVIEW

The 1788-R Remote Controller provides all the functions from the Model 1788’s 

Local Block

and 

Test

Tone Block

. For complete details on the functions in both these blocks, refer to the Model 1788 User’s

Manual. A quick reference to these basic functions is found in this manual’s Section 1.2 -The 1788-R
Remote Controller at a Glance. 

The following two sections provide further details beyond what was in the quick reference for the

Selection and Validation Block

and the 

Preset Handling Block

There is also a set of Secondary functions; Clip/Lim Metering ballistics, brightness control and software
version display, which is explained in Section 2.4.

2.2   SELECTION AND VALIDATION BLOCK

The upper portion of the 1788-R is used for selecting and validating all Model 1788s in a system chain. 

The COMM TEST button initiates a communication test, which verifies the connection status of all
Model 1788s in the system.  The COMM TEST button and the VALID LED’s will flash during the test
procedure. At the end of the test, identified units will be indicated by a solid green light in the respective
VALID LED‘s and the COMM TEST button will stop flashing. 

Whenever a Model 1788 is added to the system or right after power up, it’s recommended that you run a
communication test, though a communication test can be run at any time just to check status of the
Model 1788s. If changes are made locally on one or more of the connected Model 1788s, the communi-
cation test can be run to upload all new settings.

The VALID LED indicates the communication status of all units identified under the communication test.
A solid green light means valid communication, solid red light means invalid communication. Under
normal operation the VALID LED should never turn red.  If the Valid LED should turn red, inspect the
cabling between the Model 1788’s, and the settings in the control block, then rerun the communication
test. After the communication test only the valid units may be selected using the UNIT SELECT button. 

Specific units are selected with the UNIT SELECT buttons (illuminates when selected). When a unit is
selected all specific unit settings are transferred to the 1788-R. In Preset Edit Mode the number of units
in a preset can be modified by using the UNIT SELECT buttons. Please refer to the next Section 2.3
–Preset Handling Block.  

During the time the remote is communicating (sending or receiving information) the COMM LED will
illuminate. When one or more COMM LED’s are illuminated no new functions can be activated.

The CLIP/LIM indicator illuminates when any one of the eight channels of that particular unit is clipping
or when limiting occurs (if MicLim™ circuit is activated). To determine which channel is exhibiting clip-
ping or limiting, select the unit in question with the UNIT SELECT button and the 

Local Block

CLIP/LIM

LED indicator for the individual channel or channels will illuminate.  To be able to indicate a short
Clip/Lim event the Model 1788-R has a build-in programmable Clip/Lim memory function. This func-
tion keeps the Clip/Lim LED (both in the 

Local Block

and the 

Selection and Validation Block 

) illuminated

for a certain amount of time. This user programmable function is explained in Section 2.4 - Secondary
Functions.

8

R E M O T E   C O N T R O L L E R

-

R

Содержание 1788-R

Страница 1: ...USER S GUIDE R E M O T E C O N T R O L L E R R FOR USE WITH THE MODEL 1788 8 CHANNEL MICROPHONE PREAMPLIFIER...

Страница 2: ...ms LTD All rights reserved All Aphex products are trademarks or registered trademarks of Aphex Systems LTD Other brand and prod uct names are trademarks or registered trademarks of their respective ho...

Страница 3: ...a Glance 4 1 3 Quick Setup 6 2 0 FUNCTIONS 2 1 Overview 8 2 2 Selection and Validation Block 8 2 3 Preset Handling Block 9 2 4 Secondary Functions 3 0 INTERFACING 3 1 Interfacing 12 3 2 When Using the...

Страница 4: ...manual covers only those features functions and interfacing configurations that are specific to the 1788 R 1 2 THE MODEL 1788 R REMOTE CONTROLLER AT A GLANCE This section is meant to serve as a quick...

Страница 5: ...Engages a 12dB octave low cut filter with a corner frequency of 75Hz Load Loads preset displayed in NEXT readout This initiates a download of all current settings from connected Model 1788s except in...

Страница 6: ...22 For long communication distance 100 feet 33 meters always use the RS 422 communication link For shorter distances choose between RS 232 and RS 422 based on availability of the proper communi cation...

Страница 7: ...ation green of the VALID LED for all connected units and the COMM TEST button will no longer be lit The COMM TEST button will flash during test procedure At the end of comm test unit 1 is selected as...

Страница 8: ...the communication status of all units identified under the communication test A solid green light means valid communication solid red light means invalid communication Under normal operation the VALID...

Страница 9: ...SELECT knob the three LEDs next to the readout indicate the preset s status as follows MISMATCH when the number of units in the selected presets do not match the number of units detected in the comm...

Страница 10: ...ou want to modify 5 To save the new settings select the Next preset number using SELECT knob in which the changes will be saved and press the SNAP SHOT button If the selected preset is protected first...

Страница 11: ...te ONLY in the Selection and Validation Block By selecting the unit with the UNIT SELECT button while the CLIP LIM LED is illuminated the memo ry time is reset and the Local Block now indicates using...

Страница 12: ...gnificant different in the noise immunity between the two connections The following table supplies the key differences of the two connectors Refer to Section 3 8 Communication Ports in the Model 1788...

Страница 13: ...it can be useful to use the 1788 Remote Program alongside the 1788 R due to certain advantages it offers For instance each Model 1788 in the system as well as all of their individual channels can be g...

Страница 14: ...non sequential order they will be loaded into the 1788 R sequentially It is possible for the same preset to be applied to different scenes which means the same preset can be downloaded to several pres...

Страница 15: ...nder the terms of the warranty you must also include proof of purchase Insure your shipment and send it to Aphex Systems Ltd ATTN RA enter RA here 11068 Randall Street Sun Valley CA 91352 PH 818 767 2...

Страница 16: ...ex Systems Ltd 11068 Randall Street Sun Valley CA 91352 PH 818 767 2929 FAX 818 767 2641 Copyright 1999 by Aphex Systems LTD All rights reserved All Aphex products are trademarks or registered tradema...

Отзывы: