Apera Instruments ZenTest PH60-Z Скачать руководство пользователя страница 3

 

- 3 - 

 

Int roduct ion  

Dear Customer, 

 
Thank you for choosing Apera Instruments PH60-Z Smart pH Tester. Please carefully read this manual in order 
to properly use and maintain the product. 

 

1.1 Search “zentest smart” in Apple App Store or Google Play App Store to download the latest App for your 

tester. Turn on the Bluetooth of your phone, go to ZenTest™ App, tap              on the upper right corner, then 

select your tester to connect. 

 

 

 

 

 

 

 

 

 

 

 

1.3 For video tutorials on how to get the most out of 

ZenTest™

, please go to 

support.aperainst.com

 

1.4 This product is designed with a two-way control on both the tester and ZenTest™ App. Please refer to the 

functions available on each platform in the following table. This manual shows you how to operate the tester 

without connecting to a smartphone.   

Table 1: Funtions on 60-Z Tester and ZenTest

® 

Mobile App 

Functions 

60-Z Tester 

ZenTest Mobile App 

Display 

LED display 

1.  Basic Mode: digital calibration info 

Swipe to switch 

among various 

modes 

2.  Dial Mode: digital dial display 

3.  Graph Mode: digital graph display 

4.  Table Mode: digital real time 

measurement and history display 

Calibration 

Press buttons to 

operate 

Operate on smartphone following graphic guides 

Self-Diagnosis 

Er1 

– Er6 icons 

Detailed problem analysis and solutions 

Parameter Setup 

Press buttons to set 

up (except for P7 and 

P11) 

All parameters can be set up in Settings. 

Alarm 

The screen turns red 

when alarm triggered; 

cannot be setup 

Alarm display and alarm values can be preset for each parameter 

Data Management 

N/A 

Manual or Auto. Datalogger; notes can be added to saved data 

Data Output 

N/A 

Share data via Email 

Содержание ZenTest PH60-Z

Страница 1: ...1 ZenTest PH60 Z Smart pH Tester Kit pH Temp ORP User Manual APERA INSTRUMENTS LLC aperainst com V1 5...

Страница 2: ...2 ATTENTION Water droplets are added during production to maintain the moisture of the probe This is normal practice and should not be attributed to used product Never use the product when it s freezi...

Страница 3: ...erate the tester without connecting to a smartphone Table 1 Funtions on 60 Z Tester and ZenTest Mobile App Functions 60 Z Tester ZenTest Mobile App Display LED display 1 Basic Mode digital display cal...

Страница 4: ...t press to turn on off backlight 1 In measurement mode long press to turn on off Bluetooth receiver When turned on will be flashing when connected to smartphone will stay on 3 In parameter setting sho...

Страница 5: ...ARDS Preparation before Use 5 1 Pull out the battery insulation slip and take off the probe cap 5 2 Rinse off the probe in pure water preferably distilled or deionized water RO water or tap water is t...

Страница 6: ...0 01 standard pH buffer and repeat Step 6 3 to 6 4 will show up next to and indicating a successful 3 point calibration high low and middle points 6 7 Notes about Calibration 1 The 1st point calibrati...

Страница 7: ...n soak it in 3M KCL 3 5 hours before performing calibration again is pressed before measurement is fully stabilized Wait for to stay on screen before pressing During calibration readings being unstabl...

Страница 8: ...sured in mV It s also called redox ORP is a measure of the cleanliness of water its ability to break down contaminants A separate ORP probe ORP60 DA needs to be installed to be able to measure ORP 2 P...

Страница 9: ...ort press to adjust parameter short press to confirm Short press to exit parameter setting and go back to measurement mode 2 Auto Lock P02 Users can set the auto lock time from 5 to 20 seconds For exa...

Страница 10: ...Factory Default P08 Select Yes to recover instrument calibration to theoretical value This function can be used when instrument does not work well in calibration or measurement Calibrate and measure a...

Страница 11: ...ble damage replace the probe Instrument defect Contact us for warranty fulfillment Probe is not fully submerged in the solution Make sure the probe is immersed into solution at least 1 inch Air bubble...

Страница 12: ...ged product attributable to responsibility of APERA INSTRUMENTS LLC for a period of TWO YEARS SIX MONTHS for the probe from the delivery This limited warranty does NOT cover any damages due to Acciden...

Отзывы: