1.  Introduction 

Thank you for choosing Apera Instruments PC60-Z Smart Multi-Parameter Tester. Please carefully 
read this manual before using the product. 
 

 

Search “zentest smart” in Apple App Store or Google Play App Store to download the latest 

App 

for your tester. Turn on the Bluetooth of your phone, go to ZenTest™ App, tap 

on the 

upper right corner, then select your tester to connect. 

 
 
 
 
 
 
 
 
 
 

 

  For video tutorials on how to get the most out of 

ZenTest™

, please go to 

www.aperainst.de

 

  This product is designed with a two-

way control on both the tester and ZenTest™ App. Please 

refer to the functions available on each platform in the following table. This manual shows you how 

to operate the tester without connecting to a smartphone.   

 

Table 1: Funtions on 60-Z Tester and ZenTest

® 

Mobile App 

Functions  60-Z Tester 

ZenTest Mobile App 

Display 

LCD display 

1. 

Basic Mode: digital dcalibration 
info 

Swipe to 
switch 
among 
various 
modes 

2. 

Dial Mode: digital dial display 

3. 

Graph Mode: digital graph 
display 

4. 

Table Mode: digital real time 
measurement and history display 

Calibration 

Press buttons to 
operate 

Operate on smartphone following graphic guides 

Self-
Diagnosis 

Er1 – Er6 icons 

Detailed problem analysis and solutions 

Parameter 
Setup 

Press buttons to set 
up (except for P7 
and P11) 

All parameters can be set up in Settings. 

Содержание AI3719

Страница 1: ...1 SKU AI3719 ZenTest PC60 Z Smart 7 in 1 Tester pH Cond TDS Salinity Resistivity ORP Temp Instruction Manual APERA INSTRUMENTS Europe GmbH www aperainst de...

Страница 2: ...be Replacement 14 17 Troubleshooting Guide 14 18 Warranty 16 ATTENTION Water droplets are added during production to maintain the moisture of the probe This is normal practice and should not be attrib...

Страница 3: ...er to the functions available on each platform in the following table This manual shows you how to operate the tester without connecting to a smartphone Table 1 Funtions on 60 Z Tester and ZenTest Mob...

Страница 4: ...an be added to saved data Data Output N A Share data via Email 2 What s in the Kit 3 Battery Installation Please install batteries according to the following steps Please note direction of batteries A...

Страница 5: ...tester long press to enter parameter setting 2 In calibration mode or parameter setting short press to return to measurement mode 3 In measurement mode long press to turn off the tester short press to...

Страница 6: ...oint calibrations 4 00 10 01 1 68 or 12 45 immediately after the 1st point calibration is finished Do NOT turn off the meter before you calibrate 2nd or 3rd point Otherwise you will need to restart th...

Страница 7: ...pH electrode is damaged or broken If so please replace with a new one 2 The glass bulb or junction is severely contaminated Please use a soft brush with soap water to clean it thoroughly Then soak it...

Страница 8: ...ur certain amount of 1413 S cm and 12 88mS cm conductivity calibration solution into corresponding calibration bottles to about half volume of the bottle 3 Long press key to enter calibration mode scr...

Страница 9: ...tion is expired or contaminated 3 Check if the conductivity electrode two black rods is damaged 4 Check if the conductivity electrode is contaminated If so please use a soft brush with warm water to c...

Страница 10: ...ductivity is linear related and its conversion factor is 0 40 to 1 00 Adjust the factor in parameter setting P5 based on the requirements in different industries The factory default setting is 0 71 d...

Страница 11: ...I1166 or detergent water for 30 minutes Then use a soft brush to remove the contaminants Afterwards soak the probe in 3M KCL soaking solution for at least 1 hour Rinse it off then re calibrate the tes...

Страница 12: ...ding is locked 3 Auto Backlight P03 Users can set the automatic backlight time for 1 to 8 minutes For example if 3 minutes is set the backlight will turn off automatically after 3 minutes when the Off...

Страница 13: ...alibration is finished or the reminder setting is cancelled in the ZenTest App the Er6 icon will disappear 6 pH Back to Factory Default P08 and Conductivity Back to Factory Default P12 Select Yes to r...

Страница 14: ...ry probe will eventually age and fail even if you don t use it that often The typical service life of Apera probes is 12 24 months depending on the frequency of usage and how well you keep it clean an...

Страница 15: ...tabilizing add 1ml of 3M KCL solution to 1000ml of test solution or 1 teaspoon to 1 gallon Display similar readings in any solutions or always display 7 0 pH Broken probe If you don t find any visible...

Страница 16: ...PERA INSTRUMENTS Europe GmbH for a period of TWO YEARS SIX MONTHS for the probe from the delivery This limited warranty does NOT cover any damages due to accidental damage unauthorized repair normal w...

Отзывы: