2.16.4.5. Inspect filter element for clogging or wear and replace as necessary.
2.16.4.6. Pour alcohol into the Separator outlet line until the solvent is colorless coming out
of the filter. Then, use compressed air to blow out the line, ensuring that no
residual alcohol remains in the line between the Separator and the pump.
2.16.4.7. Reconnect the Separator outlet line and DC filter and housing, being sure to not
pinch filter O-ring (if the O-ring is swelled, replace with another O-ring).
2.16.4.8. The CO
2
return line must be cleaned after each extraction.
2.16.5.
Reassemble Separators.
2.17.
Recommended Operating Parameters
2.17.1.
Recommended parameters are intended as a starting point to be used in conjunction
with the CO
2
Phase Diagram in Appendix F.
2.17.2.
For lighter color and less wax content
2.17.2.1. Orifice Selection: .......................................... #37
2.17.2.2. Separator Pressure: ..................................... 350-380psi
2.17.2.3. Separator Chiller Setting: ............................. 64°F
2.17.2.4. Extractor Target Pressure: ........................... 1100-1300psi
2.17.2.5. Extractor Chiller/Heater Setting: ................... 70°F
2.17.2.6. Extraction Time: ........................................... 1-2 hours per pound
2.17.3.
For decreased extraction time, darker and more wax content
2.17.3.1. Orifice Selection: .......................................... #18
2.17.3.2. Separator Pressure: ..................................... 300-320psi
2.17.3.3. Separator Chiller Setting: ............................. 74°F
2.17.3.4. Extractor Target Pressure: ........................... 4000-4200psi
2.17.3.5. Extractor Chiller/Heater Setting: ................... 110°F
2.17.3.6. Extraction Time: ........................................... 15-30 min per pound