The Force Dual Phase™ Operation Manual
4
Revision Date: 4/22/2019
2. System Operation
The following operating instructions are for The Force™ Dual Phase: 5000-5Lx5LDP, 20Lx20LDP
and 40Lx40LDP, CO
2
-based
Botanical Oil Extraction systems. Instructions assume that chiller and
CO
2
Booster Pump are OEM (Original Equipment Manufacturer) supplied. Failure to follow the
instructions provided below may void the warranty of the system.
2.1.
The Force™ Dual Phase 5000psi System Overview
Figure 1. System Overview
2.2.
Automation Systems Overview
2.2.1.
The Human Machine Interface (HMI) is a 10-inch color touch screen. Almost all of the
inputs, outputs and human/machine interactions are managed through the HMI, with the
exception of the Air Compressor and Chiller, which operate independently.
2.2.2.
The HMI has two functions; 1) to provide information and 2) to accept inputs from the
operator. Descriptions of some of the interactions:
2.2.2.1. If a display value or message is colored orange, an operator must take action
before progressing forward.
2.2.2.1.1.
Orange indicates that operator activity is required before the Start
button can be depressed. Messages highlighted orange are indicative of a
scheduled maintenance interval being reached.
2.2.2.2. Red messages indicate that a component of the system has either failed
to reach the minimum operating pressures or temperatures, or that a component of
the system exceeded the programmed operating limits.
2.2.2.3. Red messages are typically reserved for alarms that could potentially shut
down the machine if the condition causing the alarm is not returned to normal.
Extractor
Chiller/Heater
Separation
Vessels
Collection
Cups
Extraction
Vessel
HMI / Touch
Panel
Diaphragm
Pump
Liquid
Pump
Hoist Arm
Separator
Chiller