Installation Manual: The Bambino™ and The Transformer™
19
Revision Date 4/9/2019
3.3.6. Electrical Connections
3.3.6.1.
Connection between Motor and Motor Starter Enclosure
– Connect the diaphragm
compressor motor wires to the motor enclosure on the back of the Apeks system as shown
in Figure 11 by inserting labeled wire T1 to the bottom T1 of the motor starter, T3 to T3,
and ground wire to the ground terminal on the din rail immediately to the left of the motor
starter.
NOTE
: 3 Phase motors require a wire termination in T2 as well. Refer to Appendix
B for torque requirements.
Figure 9:
Air line connection
Figure 10:
Electrical connection panel