  B.  ELEMENT SIZE VERIFICATION

    All elements are marked with both wattage and voltage.  Verification can be made by measuring the ohms    

  resistance across the terminals of the elements.  Element must be disconnected from the circuit.  The following  

  table gives resistance in ohms for all elements used in commercial electric water heaters.

  Element ohms resistance  should be within ±5% of the above values.

  Examples: Elements with an ohm resistance of 14 ohms indicates that it is either a 3,000 watt/208 volt element  

 

and/or a 4,000 watt/240 volt element (dual rated type).

 CAUTION

NEVER OPERATE THE HEATER WITHOUT FILLING WITH WATER PER THE FILLING INSTRUCTIONS. FAILURE 

TO DO SO WILL DAMAGE INTERNAL PARTS.

 

     

OHMS RESISTANCE TABLE

 

 

 

 

VOLTAGE

  WATTAGE 

208 

 240 

  480

 

2000 

21.63 

28.80 

115.20

 

3000 

14.42 

19.20 

76.80

 

4000 

10.82 

14.40 

57.60

 

4500 

9.61 

12.80 

51.20

 

5000 

8.65 

11.52 

46.08

 

6000 

 7.21 

 9.60 

38.40

   

Number 

KW               Single (1) phase            Three (3) Phase

   KW 

of 

  Each

 Input  Elements  Elements  208V 

240V  480V  208V  240V  480V

   6 

 

2.0 

28.8 

25.0 

12.5 

16.7 

14.4 

 7.2

   9 

 

3.0 

43.3 

37.5 

18.8 

25.0 

21.7 

10.8

  12 

 

4.0 

57.7 

50.0 

25.0 

33.3 

28.9 

14.4

  13.5 

 

4.5 

64.9 

56.3 

28.1 

37.5 

32.5 

16.2

  15 

 

5.0 

72.1 

62.5 

31.3 

41.6 

36.1  18..0

  18 

 

6.0 

- - - - 

75.0 

37.5 

- - - -  43.3 

21.7

  18 

 

3.0 

86.5 

- - - -   - - - -    50.0  - - - -  - - - - 

  24 

 

4.0 

115.4  100.0  50.0 

66.6 

57.7 

18.9

  27 

 

4.5 

129.8  112.5 

56.3 

74.9 

65.0 

32.5

  30 

 

5.0 

144.2  125.0  62.5 

83.3 

72.2 

36.1

  36 

 

6.0 

- - - - 

150.0  75.0 

- - - -  86.6 

43.3

  36 

 

4.0 

173.1 

- - - - 

- - - - 

99.9  - - - -  - - - -

  40.5 

 

4.5 

194.7  168.8  84.4 

112.4  97.4 

48.7

  45 

 

5.0 

216.3  187.5  93.8  124.9  108.3  54.1

  54 

 

6.0 

- - - - 

225.0  112.5  - - - -   129.9  65.0

3

6

9

FULL LOAD CURRENT IN AMPERES

Содержание AITCE31-119

Страница 1: ...r S And Models A STCE31 50 80 119 A ITCE31 50 80 119 Commercial Electric Water Heaters CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFOR...

Страница 2: ...ar the electrical system of the heater Never touch electrical components with wet hands or when standing in water REQUIRED ABILITY CONVERSION OF ANY WATER HEATER LISTED IN THIS MANUAL REQUIRES ABILITY...

Страница 3: ...eting the unit conversion CONVERSION KIT NUMBER TABLE Models Allowed For Conversion Desired Input Conversion Kit No At Desired Voltage Total KW Element KW 208V 240V 277V 480V CSB or I S TCE models wit...

Страница 4: ...elements to appropriate storage bin C Open the appropriate conversion kit and remove the elements Check each element to ensure correct voltage and wattage D Install the new element starting it by hand...

Страница 5: ...HASE TO THREE PHASE 1 Disconnect blue wires from terminal L 1 2 Disconnect yellow wires from terminal L 2 3 Connect all blue wires and yellow wires to terminal L 3 4 Incoming power will be connected t...

Страница 6: ...L 3 5 Incoming power will be connected to terminals L 1 L 2 and L 3 at job site VI CAUTION Recheck all terminals for tightness proper wiring per schematic and neatness of wiring Heater should be no l...

Страница 7: ...HIPPING CRATE Close and tape the plastic flap on front of crate CHECK LIST All affected parts have been installed properly and have been checked for tightness All affected wires have been checked for...

Страница 8: ...SO WILL DAMAGE INTERNAL PARTS OHMS RESISTANCE TABLE VOLTAGE WATTAGE 208 240 480 2000 21 63 28 80 115 20 3000 14 42 19 20 76 80 4000 10 82 14 40 57 60 4500 9 61 12 80 51 20 5000 8 65 11 52 46 08 6000 7...

Страница 9: ...9 NOTES...

Страница 10: ...10 NOTES...

Страница 11: ...11 NOTES...

Страница 12: ...12 125 Southeast Parkway Franklin TN 37068 1 800 433 2545 apcom inc com...

Отзывы: