CONVERSION GUIDELINES
Be sure to read and understand the conversion limitations and instructions prior to conversion.
1. No addition or substraction of heating elements are allowed in the conversion process;
2. Conversion kits are designed for specific voltage with Delta configuration, no other configuration or voltage is
allowed;
3. Refer to “Branch Circuit Section” in User’s Manual for electrical specifications;
4. Check all water and electrical connections for tightness after conversion.
TO USE THE TABLE:
1. Find the element number of the heater that you wish to convert.
2. Find the total kilowattage under “Desired Input” column, then move across the Table on same line to voltage
desired. The kit number required for the conversion will be the one where the desired KW row intersects the voltage
column.
3. Order the appropriate kit number.
4. Follow the conversion instructions detailed on pages 9 through 13 to complete conversion.
5. Fill out the check list on Page 12 after completing the unit conversion.
CONVERSION KIT NUMBER TABLE
Models Allowed
For Conversion
Desired Input
Conversion Kit No. At Desired Voltage
Total KW Element KW
208V
240V
277V
480V
CSB or
(I, S)TCE
models with
3 Elements
6
2
9003335005
9003348005
9004115005
9003363005
9
3
9003336005
9003349005
9004116005**
9003364005
12
4
9003337005
9003350005
9004117005
9003365005
13.5
4.5
9003333005
9003345005
9004118005**
9003360005
15
5
9003334005
9003346005
9004119005**
9003361005
18
6
N/A
9003347005
9004120005
9003362005
CSB or
(I, S)TCE
models with
6 Elements
18
3
9003340005
9003354005
9004121005**
9003369005
24
4
9003341005
9003355005
9004122005
9003370005
27
4.5
9003338005
9003351005
9004123005**
9003366005
30
5
9003339005
9003352005
9004124005**
9003367005
36
6
N/A
9003353005
9004125005
9003368005
CSB or
(I, S)TCE
models with
9 Elements*
36
4
9003344005
9003359005
9004126005
9003374005
40.5
4.5
9003342005
9003356005
9004127005**
9003371005
45
5
9003343005
9003357005
9004128005**
9003372005
54
6
N/A
9003358005
9004129005
9003373005
* No conversion kits available for 50 gallon capacity 9 element models equipped with surface-mounted thermostat.
** Indicates the conversion kit with Incoloy Elements.