IMPORTANT SAFTEY INSTRUCTIONS

1)

 

Read These Instructions

2)

 

Keep These Instructions

3)

 

Heed All Warnings

4)

 

Follow All Instructions

5)

 

Do Not Use this Apparatus near water

6)

 

WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture. Do not expose the apparatus to dripping or splashing. Do not place objects
containing liquids, such as vases, on the apparatus.

7)

 

For safety the AC supply must include third wire protective ground connection.

8)

 

Do not block any ventilation openings at the front and rear. Install in accordance with the
manufacturer’s instructions.

9)

 

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus
(including amplifiers) that produce heat.

10)

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. a grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong is provided for your safety. If the provided
plug does not fit your outlet consult an electrician for replacement of the obsolete outlet.

11)

 

Protect the power cord from being walked on or pinched particularly at plugs convenience
receptacles and the point where they exit the apparatus.

12)

 

Unplug this apparatus during lightning storms or when unused for long periods of time.

13) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has

been damaged in any way, such as power supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally or has been dropped.

Содержание ProDesk-4

Страница 1: ...ProDesk 4 OWNER S MANUAL APB DynaSonics Inc 20 West End Road Totowa New Jersey 07512 U S A Tel 973 785 1101 Fax 973 785 1105 Web www apb dynasonics com...

Страница 2: ...APB DynaSonics 2...

Страница 3: ...duce heat 10 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other a grounding type plug has two blades and a third gro...

Страница 4: ...NDS 20 STEREO LINE INPUT MUTE SOLO AND LEVEL CONTROL 21 STEREO LINE INPUT BUS ASSIGNMENT AND BALANCE 22 STEREO LINE INPUT REAR PANEL CONNECTORS 23 MASTER SECTION 24 AUXILIARY BUSES 1THRU 6 24 GROUP OU...

Страница 5: ...TEXT THAT FOLLOWS AND HAVE THE FOLLOWING MEANINGS TO AVOID ELECTRIC SHOCK FOLLOW THE INSTRUCTION NEXT TO THIS SYMBOL TO AVOID AN UNSAFE CONDITION FOLLOW THE INSTRUCTION NEXT TO THIS SYMBOL PSU A PSU...

Страница 6: ...openings must not be covered while the system is on Low noise internal fans provide air movement OPERATION Turn on each power supply using the rocker switch on the PS panel Normal operation is signale...

Страница 7: ...EMENT OF POWER SUPPLY UNITS 1 Disconnect the AC power cord 2 Remove four screws that secure the PS unit in the console chassis marked with the symbol in the diagram Pull on the power supply handle and...

Страница 8: ...d unsafe internal temperature Approvals USA Recognized power supply with ETL marking and listing USA and Canada UL60065 7th Edition Electrical Safety Europe EN60065 7th Edition Electrical Safety Europ...

Страница 9: ...y questions or comments about this APB DynaSonics product please do not hesitate to contact us at Tel 973 785 1101 Fax 973 785 1105 e mail info apb dynasonics com Manual Scope This manual is not inten...

Страница 10: ......

Страница 11: ...ll step to next mode LED will change color If MODE switch is not re pressed when LED is still illuminated meter status remains in its current mode STATUS LED Additional Function If Mute All is activat...

Страница 12: ...ted XLR or 1 4 Polarity Reverse Switch When depressed reverses the electrical input polarity of any microphone or line level input signal Use of this control may alter the sound quality of an input re...

Страница 13: ...gh mid frequency band EQ between 400Hz and 8kHz The bandwidth is approximately one octave High Mid Level Control Adjust the high mid band boost cut between 15dB there is a detent at the center 0 posit...

Страница 14: ...the Aux Pre Source select switch above Aux 1 2 Stereo Switch Reconfigures the individual Aux 1 and 2 controls from two level controls to a Pan control 1 and a Level control 2 This enables a stereo mi...

Страница 15: ...e sample points in the channel s signal path approach within 3dB of clipping Please Note The overall channel meter should be considered as 2 separate monitoring indicators the Green and Yellow LEDs ar...

Страница 16: ...ems this bus can be used as the primary output leaving the L R output available for stereo recording It is usually used in LCR installations to feed a discrete signal to the center speaker It may also...

Страница 17: ...d has an output impedance of 100 unbalanced and the insert return has an input impedance of 5k unbalanced Operating level is 4dBu NOTE The user should ensure that any device inserted into the channel...

Страница 18: ...Pre Aux Feed Aux Send Blend Control When the Split Track mode switch is pressed the Pre Aux Feed control will be active This control allows the operator to adjust the mono mixture of the left right in...

Страница 19: ...y Level Control Bell shape Adjusts the high mid frequency bell shaped cut boost between 15dB Use of this EQ control will affect both the left and right signal paths The Low Mid EQ has a center frequen...

Страница 20: ...If Split Track is active both of the sends receive the same mono mix from the either the Pre fader Blend control when in Post or the Pre Aux Feed control when in Pre Aux Level Control 3 Adjusts the le...

Страница 21: ...luminate without first having the Yellow LED lit This usually will be caused by excessive preamp levels and a subsequent cut in the EQ or there may be a compressor or limiter in the channel s insert p...

Страница 22: ...nt Switch Assigns the post fader summed channel signal to the Center mix bus In mono sound systems this bus can be used as the primary Center output leaving the L R output available for stereo recordi...

Страница 23: ...w signal into the Right side of the channel Left And Right RCA Input Connectors Provides for unbalanced line level inputs to the channel s left and right inputs Design level is 10dBV Input impedance i...

Страница 24: ...the monitoring and meter system in mono both L R sides of the solo system are fed When both Aux 1 Aux 2 AFL buttons are pressed Aux 1 will feed the left solo bus while Aux 2 will feed the right solo...

Страница 25: ...gnal levels on the associated Group mix bus Varying intensity Green indicates proper bus levels while red indicates approaching overload within the Group circuitry Overload is sensed after the mix amp...

Страница 26: ...associated Left Right Center and Mono signals being fed into the associated matrix system A single switch in the Main output section above the Center fader determines if these signals are derived pre...

Страница 27: ...fader feed Fader Flip Swap Mono Aux 6 controls This function is described earlier and in more detail in the Aux Master section The 3 controls and indicators for the Mono bus bi color sig LED 100mm fa...

Страница 28: ...ssing or effects electronics can be inserted into the bus signal path after the summing amp Examples of external devices include additional equalization notch filters compressors limiters etc The iner...

Страница 29: ...more information about the USB features on the ProDesk Stereo EQ High Low Freq EQ is available to adjust the tonal balance of the selected mixed input sources Both controls have a shelving response Hi...

Страница 30: ...des M The Main Mono bus Mono bus feeds both left right sides Mtx 1 2 Matrix bus 1 2 Matrix 1 feeds left side Matrix 2 feeds right side Aux 1 2 Aux bus 1 2 Aux 1 feeds left side Aux 2 feeds right side...

Страница 31: ...n and communication Burr Brown PCM2900 A USB B Type connector is provided The USB Audio Out to the computer can be driven from the same audio signals feeding the Stereo Record Out the top panel USB On...

Страница 32: ...en this switch is depressed the monitor out is summed to a mono signal When this button is Up the sources maintain their stero images Headphone Level Control This control adjusts the level being fed t...

Страница 33: ...ph faster attack Ave Peak Combination of both When both are active Peak shows as a single LED above an Averaging bargraph The same decay time is used for both to allow the Peak LED to always be visibl...

Страница 34: ...tor to the selected buses TB On Master Talkback Switch internally illuminated This is a smart switch that will act as either a momentary or latching switch depending on how it is pressed Momentary Pre...

Страница 35: ...ith a single external command This feature can be used when the PA system is required to be silenced during safety announcements or if a system wide mute is needed for any reason The 2 pin Phoenix con...

Страница 36: ...re accessed by removing the Master Interface Panel to gain access to and adjust the position of the 4 removable jumpers Remove the 4 corner screws Philips head and pull the complete Interface assembly...

Страница 37: ...r Inp Inp Mstr Inp Inp Inp Inp Inp Mstr Inp Inp Inp Inp Inp Mstr Inp Inp Inp Length L2 Inch mm 30 72in 780 3mm 38 82in 986 1mm 46 92in 1191 8mm 55 02in 1397 5mm 63 12in 1603 3mm Weight lbs kg 90 41 10...

Страница 38: ...dB Channel Routing 80dB Channel Pan Isolation 80dB Channel to Channel Isolation 90dB Aux Send Attenuation 90dB Aux Pan Isolation 70dB Input Output Impedances Channel XLR Input 3K Balanced with or with...

Страница 39: ...ProDesk 4 OWNER S MANUAL 39...

Страница 40: ...APB DynaSonics ProDesk 4 Owners Manual Rev 0 91 July 2009...

Отзывы: