E n g l i s h
| 6
Ovens are supplied with terminals, as in the image. To connect to the mains see the label in the manual and
stuck to the lower part of the back of the appliance near the Information Plate .
Proceed as follows to connect the power supply
wire to the terminal board:
-
(A1) Loosen the tops of the cable gland
and open the bottom part of the back
of the appliance by loosening the
screws.
-
(A2) Feed the new cable through the
cable gland.
-
(A3) Connect the power supply cable
voltage to the terminal strips following
the connection diagram on the label
on the back of the appliance. Only
connect what is indicated inserting the
copper bridge and the electricity cable
together under the screws, in the
tightening direction, so the cable and
the bridge are tightly fixed by
tightening the screw. The type of cable to be used (HO7RN-F) is indicated on the label for each
connection and the cross-sections in
mm²
.
-
( A4 ) Close the bottom part of the back of the appliance by tightening the screws and fit the cable
by tightening the cable gland top.
An incorrect connection could lead to the terminal board overheating which could lead to a blowout and
electric shock.
Check that all the connections are tight before connecting the oven to the mains.
PE = Yellow/Green :
“EARTH” power conductor.
N = Blue :
neutral conductor.
L1, L2, L3 = Brown, Grey, Black :
phase conductors
Check there is no static discharge between live and earth. Check the limit switch continuity between the
external casing and the earth wire of the mains. We recommending using a multi-tester to carry out these
operations
CABLE SUBSTITUTION
This must be carried out by a qualified and authorised technician. The earth wire must always be yellow
green.
ATTENTION: When connecting the power cable, arrange the different conductors so that the earth one
(yellow-green) is three cm longer than the other wires.
Proceed as follows to connect the power supply wire to the terminal board:
o
( A1 ) Loosen the tops of the cable gland and open the bottom part of the back of the appliance by
loosening the screws.
o
( A2 ) Loosen the terminal screws and feed the cable conductors through. Remove the old cable
from the cable gland.
o
( A3 ) Feed the new cable through the cable gland. Connect the new cable’s conductors to the
terminal following the connection diagram on the label at the lower part of the back of the oven.
Only connect what is indicated inserting the copper bridge and the electricity cable together under
the screws, in the tightening direction, so the cable and the bridge are tightly fixed by tightening