be regulated according to the speed of the main ventilator, as selected with the remote control. The
connection between the re oxygenising unit and outside air access point is made using a Ø150 flexible duct.
5.5 PILOT UNIT AND SATTELITE UNIT
The UC1200 unit may control one or more remote units (denominated satellites). The satellites do not have
their own electronic control circuitry but is controlled by the main unit. This solution reduces the overall cost
of the investment, provided the interconnected machines may always work in the identical manner. The main
unit is denominated the
pilot unit
.
A pilot unit of type AFC System or Nature System will control up to two remote filter units and three re
oxygenising units. A pilot unit of type Basic System will control one remote filter unit and two re oxygenising
units.
5.6 ELECTRICAL
CONNECTIONS
All electrical connections should be carried out by a qualified electrician.
5.6.1 Electrical
connection
The electrical mains supply must be connected exclusively to the (pilot) filter unit. Re oxygenising units and
possible satellite units all receive their power from the pilot filter unit.
1) Open the contacts cover plate
removing the fixing screws
2) Insert the power cable through the
cable gland in the plate and secure.
3) Connect the power to the contacts
1-2-3 on the terminal block
4) Close the cover plate