57
The electronic circuit will light up an eventually block of filtration. The causes often can be resolved by a
small operation.
TYPE OF ALARM
CAUSE
OPERATION
electrostatic cell dirty
carry out normal maintenance
electrostatic cell not properly clean
if small dirty areas have remained, washing
must be carried out again
electrostatic cell damp
dry the cell thoroughly and particularly in the
zone of the insulators
electrostatic cell not properly rinsed
there may be detergent on the insulators; the
cell must be thoroughly rinsed again
small bodies trapped between the
collection blades
the foreign bodies deposited on the blades
must be removed
electrostatic cell short circuited due to
breakage of an ionisation wire
the wire must be removed and replaced
immediately
green Led
FILTER OK
is flashing
electrostatic cell short circuited due to
collection blade being bent
the blade must be straightened (call a
specialised technician)
It is possible that the operating status of the machine can be modified with some infrared remote control
units for television sets or banknote readers for videogames by modifying the speed fan and the status of
the machine. Check that this does not happen by pointing the TV remote control at the Air Purifier and press
the ON/OFF button.