28
Press the
[CLR]
key to exit from this function.
6-8-3 Middle Trace (MED)
Press the
[FUNC]
key and press the
[9]
key to select the
Middle Trace
.
The middle height of traces are calculated and displayed on the LCD. The effect is a
‘wave’ of activity, and is useful for accessing band activity over a relatively short period of
time.
Once activated, the buffer size must be allocated between 2 and 4 frames. The number
of frames can be entered by the numeric keypad followed by the
[ENT]
key.
While the buffer is loading, the number of frames is indicated until the programmed
number has been sampled. After this point, the specified number of frames will be
averaged on an on-going basis and the middle value of level will be displayed.
Press the
[CLR]
key to exit from this function.
6-9 Waterfall Function
Your SDU5600 has a built-in
Waterfall Function
.
The
Waterfall Function
allows the display of incoming signals by a time frame. The
signals are painted with a color according to their levels.