12
(Note: This function is available only when the receiver model is set to
[Other
(10M)]
or
[Other (45M)]
.)
6-2 Companion Receivers
Your SDU5600 may be used with the following companion receivers.
(Note: Some receivers require modifications.)
Receiver menu Model number Remarks
============================================================
3
AR5000A Set External IF output
AR5000 3 to EXT-IF 1
AR5000
----------------------------------------------------------------------------------------------------------
AR3000A AR3000A 10.7 MHz IF modification required
Baud rate: 4800 bps
----------------------------------------------------------------------------------------------------------
AR8600(10M) AR8600MKII 10.7 MHz all mode modification
required
----------------------------------------------------------------------------------------------------------
AR8600(45M) AR8600MKII 45.05 MHz IF output modification
required
----------------------------------------------------------------------------------------------------------
AR8200 AR8200MKII 45.05 MHz IF output modification
AR8200MKIII & CC8200A required
-----------------------------------------------------------------------------------------------------------
AR-ONE AR-ONE Set IF output frequency
------------------------------------------------------------------------------------------------------------
RFU5600 RFU5600 Internal RF adapter
------------------------------------------------------------------------------------------------------------
IC-R8500 ICOM ® IC-R8500
------------------------------------------------------------------------------------------------------------
IC-R7100 ICOM ® IC-R7100 Optional CT-17 required
------------------------------------------------------------------------------------------------------------
Other (10M) Receiver with 10.7 MHz IF
-------------------------------------------------------------------------------------------------------------
Other (45M) Receiver with 45.05 MHz IF
==============================================================
(Note: There is no guarantee for operation with other manufacturer’s receivers.)
6-3 Receiver Settings
This is to perform settings for the companion receiver.
(Note: This setting will not be available if the connected receiver is selected as
Other (10M) or Other (45M). Also, if the communication between the SDU5600
and the receiver is not properly established, this setting will not work.)