background image

-L*A1AW  12/12-

[Address]

Anywire Corporation

:Contact by mail

Contact

[email protected]

:Contact by website

http://www.anywire.jp

Headquarters :1 Babazusho, Nagaokakyo-shi, Kyoto 617-8550 JAPAN

Printed in Japan 2016, 2017    UMA-13311C-EN

Содержание ASLINKAMP L-A1AW Series

Страница 1: ...mpany shall not be liable for any damages consequential or incidental to a malfunction of the delivered product Repair at cost After the expiration of the warranty period any troubleshooting or repair...

Страница 2: ...ator BT0 polar to the terminal on the transmission line farthest from the AnyWireASLINK master Supply current on the transmission line DP DN Total length 50m or less 1 25mm2 0 75mm2 MAX 2A MAX 1 2A MA...

Страница 3: ...24V DC stabilized power supply Two wire terminal Four wire terminal 24V 0V 24V 0V PE AnyWireASLINK master General purpose power supply filter Use if necessary If any of the side by side lines of DP D...

Страница 4: ...V 0V Four wire terminal A B 24V 0V 24V 0V PE Filter notation in the drawing General purpose power supply filter Use if necessary General purpose power supply filter Use if necessary LOAD LINE EAC 06 4...

Страница 5: ...unit Refer to P6 Decide the maximum number of extended devices within the range meeting the conditions below Extension Base Example 1 Considering based on the limit of I O points LA A1AW Input 16 poi...

Страница 6: ...it is not used Example of local power supply To LP4 WW 10P crimped transmission line link connector FK4 125 100 LP4 WR 10P DP DN 24V 0V Master unit Master unit A D Circuit A D Circuit Control circuit...

Страница 7: ...DP DN of the terminal 2 Setting is required for all AnyWireASLINKs devices Open the protection cover of the set analog input unit and direct the address writer to the setting port of the unit as show...

Страница 8: ...Ex During 12 mA conversion LINK V mA ALM LINK V mA ALM About 3 seconds Display example during operation L A1AW 8 12 Data Structure Before shipment 0 Reference point shift mode 14 15 Conversion data 1...

Страница 9: ...he AnyWireASLINK system and turn on the power Re connect to the AnyWireASLINK system The ASLINKAMP maintains the address 255 default setting Set any address other than 255 The ASLINKAMP has an address...

Страница 10: ...00 16200 0 Over the upper limit value 200 Under the lower limit value 0 Over the upper limit value 200 Under the lower limit value 16000 16200 0 Over the upper limit value 200 3 8mA 0 95V 0 2mA Under...

Страница 11: ...5Vp p max 512 max IN 256 OUT 256 Up to 128 units Bus type Multi drop method T branch method Tree branch method Connection mode Transmission line disconnection transmission line short circuit transmiss...

Страница 12: ...2 Address Anywire Corporation Contact by mail Contact info_e anywire jp Contact by website http www anywire jp Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Printed in Japan 2016 2017 U...

Отзывы: