73 (136)
#
Name
Access
Type
Default Value
Comment
13
ADI translation
Get
Array of
Struct
{
UINT16
UINT16
}
Empty
This attribute can be used by the application to im-
plement objects in the communication profile specif-
ic CoE object area (1000h - 1FFFh). Objects
already implemented in the module cannot be re-
placed by ADIs.
The attribute is implemented as an array of packed
structs of two UINT16. The first UINT16 contains
the ADI instance number, the second contains the
object index that the ADI shall correspond to.
See
ADI Translation, Example, p. 74
14
(Reserved)
-
-
-
(Reserved for future use)
15
Object subindex
translation
Get
Array of
Struct
{
UINT16
UINT16
UINT8
}
Empty
This attribute can be used by the application to im-
plement subindices of objects in the profile specific
CoE object area (0x1000-0x1FFF). Subindices al-
ready implemented in the module cannot be re-
placed by ADIs and this attribute can only be used
to add subindices to objects explicitly defined in the
module to be extendable.
The attribute is implemented as an array of packed
Structs of two UINT16 and one UINT8. The first
UINT16 contains the ADI instance number, the sec-
ond contains the object index that the ADI shall cor-
respond to. The UINT8 contains the subindex of the
latter object that the ADI shall correspond to.
An object dictionary index/subindex entry may only
be translated to an ADI of type VAR. Translating the
entry to an ADI of type ARRAY or RECORD is not
supported.
See:
Object Subindex Translation, Example, p. 74
16
Enable FoE
Get
BOOL
TRUE (=1)
This attribute enables/disables functionality related
to File access over EtherCAT. If FoE is disabled it is
not possible to upgrade firmware via EtherCAT or
access the Application File System Interface Object
(EAh) via EtherCAT.
FoE is not supported for Anybus IP.
17
Enable EoE
Get
BOOL
TRUE (=1)
Enables/Disables functionality related to Ethernet
over EtherCAT. If EoE is disabled the module will
not accept any mailbox requests of EoE type and no
IT functionality in the module will be usable.
18
Change shift reg
switch
functionality
Get
BOOL
FALSE (=0)
Normally when running shift register operation
mode, switch 1 is used for the last octet of the IP ad-
dress and switch 2 is used for the Device ID. If this
attribute is set to TRUE this behavior is changed so
switch 1 is used for Device ID and switch 2 is used
for the last octet of the IP address.
19
Set Device ID as
Configured sta-
tion alias
Get
FALSE (=0)
Normally the Configured station alias value can only
be set from the EtherCAT configuration tool. This is
the case when this attribute is either false or not im-
plemented. If this attribute is set to True, the value
set to instance 1 of the network configuration object
(Device ID) will be set to the configured station alias
as well (both the register 0x0012 and the EEPROM).