41 (136)
Instance Attributes (Instance #11, Host name)
This instance holds the host name of the module. Changes are valid after reset..
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“Host name”
(Multilingual, see
2
Data type
Get
UINT8
07h (= CHAR)
3
Number of elements
Get
UINT8
40h (64 elements)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
Array of
CHAR
Host name, 64 characters (pad with space to full length)
Instance Attributes (Instance #12, Domain name)
This instance holds the domain name. Changes are valid after reset..
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“Host name”
(Multilingual, see
2
Data type
Get
UINT8
07h (= CHAR)
3
Number of elements
Get
UINT8
30h (48 elements)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
Array of
CHAR
Domain name, 48 characters (pad with space to full length)
Instance Attributes (Instance #13, SMTP Server)
This instance holds the SMTP server address. Changes are valid after reset..
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“SMTP server”
(Multilingual, see
2
Data type
Get
UINT8
07h (= CHAR)
3
Number of elements
Get
UINT8
40h (64 elements)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
Array of
CHAR
SMTP server address, 64 characters. Dotted decimal format or
server name(pad with space to full length)