background image

11

P/N 1011443 Rev. C 08/17

Problem

Possible Cause

Corrective Action

Control Display flashes PLt 

continuously. Buns not toasting 

properly.

Platen temperature is below 545 °F (285 °C).

Allow the unit to warm up for 30 minutes and then recheck. If the 

Control Display still flashes PLt, contact your maintenance person 

or Antunes Technical Service for service.

Failed Platen Thermocouple.

Contact your maintenance person or Antunes Technical Service for 

service.

Failed Control Board

Control Display flashes Er 10 

continuously.

Control Compartment ambient temperature is 

above 150

 

°F (66

 

°C)

Verify side vents on toaster are unblocked and not near other 

heating appliances. If problem persists, contact your maintenance 

person or Antunes Technical Service for service.

Failed Cooling Fan.
Failed Control Board

Control Display Flashes SSr con-

tinuously. Buns Burn.

Failed Front Platen Solid State Relay.

Contact your maintenance person or Antunes Technical Service for 

service.

Failed Control Board.
Failed Front Platen Thermocouple.

Control Display flashes Er 12 

continuously. Buns not toasting 

properly.

Loose Platen Thermocouple connection on Con-

trol Board or the Platen Thermocouple is open.

Re-secure the Platen Thermocouple to the Control Board. If the 

Control Display still reads Er 11, check the Thermocouple for 

continuity. Contact your maintenance person or Antunes Technical 

Service for service.

Failed Control Board.

Control Display flashes Er 11 

continuously. Buns not toasting 

properly.

Shorted Platen Thermocouple to ground.

Disconnect and re-secure the Platen Thermocouple connection to 

the Control Board. If the Control Display still reads Er 10, check the 

Thermocouple for continuity. Contact your maintenance person or 

Antunes Technical Service for service.

Failed Control Board

Control Display flashes StoP.

Mechanical bind in one or both conveyors.

Enter “user mode” to check the motor speed. Check both convey-

ors for mechanical binds. Test the motor. Replace necessary parts. 

Contact your maintenance person or Antunes Technical Service for 

service.

Worn or damaged Ball Bearings.
Drive chain or sprockets damaged.
Failed Motor.
Failed Control Board.

Control Display flashes SpEd.

Mechanical bind in one or both conveyors.

Enter “user mode” to check motor speed. Check both conveyors for 

mechanical binds. Replace necessary parts. Contact your mainte-

nance person or Antunes Technical Service for service.

Worn or damaged Ball Bearings.
Conveyor chains loose or damaged.
Drive chain or sprockets damaged.

Crowns and/or Heels must be 

forced into the toaster. Buns 

sticking and burning.

Belts are dirty, worn, or damaged (replace every 

2-4 months).

Clean or replace Belts as described in the Maintenance section of 

this manual.

Buns do not meet specifications.

Contact your bun supplier.

Buns not toasting adequately.

Compression Setting is incorrect.

Use the recommended setting of 4 for Crowns and 3 for Heels.

One of the Conveyor shafts is stuck in the lower 

lock position.

Inspect positions of the shafts as described in the Maintenance 

section of this manual.

Either both Upper/Lower Conveyor locks are not 

properly locked in place.

Inspect the proper position of the locks as described in the Mainte-

nance section of this manual.

Buns do not meet specifications.

Contact your bun supplier.

Motor settings are incorrect.

Verify that the motor setting is set to 4000 as described in the 

Programming section of this Manual.

Compression side door will not 

close.

Either both Upper/Lower Conveyor Locks are 

not properly locked in place.

Inspect the proper position of the locks as described in the Mainte-

nance section of this manual.

The lock on the Compression Side Door is in the 

locked position when trying to close the door.

Turn the lock to the unlocked position before closing the door.

Fan is making an unusual sound.

Failed Cooling Fan.

Verify vents on toaster are unblocked and not near other heating 

appliances. Clean fans as described in the Maintenance section of 

this manual. If problem persists, contact your maintenance person 

or Antunes Technical Service for service.

Cooling Fan is dirty and needs to be cleaned.

Control Display flashes HL con-

tinuously. Buns are not toasting 

properly.

Hi-Limit Control is tripped.

Allow the unit to cool and reset the Hi-Limit Control. If it trips again, 

contact your maintenance person or Antunes Technical Service for 

service.

TROUBLESHOOTING

Содержание GST-2V

Страница 1: ...P N 1011443 Rev C 08 17 Gold Standard Toaster Wendy s owner s manual Model GST 2V Manufacturing Numbers 9210980 www antunes com ...

Страница 2: ...tenance y y Damage caused by abuse or careless handling y y Damage from moisture into electrical components y y Damage from tampering with removal of or changing any preset control or safety device TABLE OF CONTENTS Purchased From Date of Purchase Model Number Serial Number Manufacturing Number IMPORTANT A J Antunes Co reserves the right to change specifications and product de sign without notice ...

Страница 3: ...t be in accordance with lo cal electrical codes and any other applicable codes y y Do not clean this appli ance with a water jet WARNINGS Be advised of the following warnings when operating and performing mainte nance on this unit y y If the supply cord is damaged it must be replaced by the manu facturer or its service agent or a similarly qualified person in order to avoid a hazard y y Do not mod...

Страница 4: ... 17 SPECIFICATIONS Model Mfg No Volts Watts Hertz Plug Description GST 2V 9210980 208 2000 60 NEMA 6 20P 20 Amp 250 Volt Right Angle Model Mfg No Width A Depth B Height C GST 2V 9210980 20 508 mm 9 227 mm 21 5 8 549 mm A C B ...

Страница 5: ...ification label and power cord warning tag Figure 1 GST 2V Toaster OPERATION 1 Press and release the Power button to turn the toaster on Allow the toaster to warm up until USE ap pears in the display See Figure 2 2 Set the Compression Knobs to the desired setting The recommended Compression Settings are CROWN 4 HEEL 3 3 Insert product into the appropriate lane on the Bun Feeder according to Bun Fe...

Страница 6: ...ons 9 Press and hold the PROGRAM but ton to save any changes NOTE The unit exits Manager Mode after 30 seconds of keypad inac tivity SAFETY FEATURES Hi Limit Control A Hi Limit Control turns off electrical power to the heaters and control circuits and displays HL if the unit overheats To reset the control 1 Let the unit cool for 15 minutes 2 Locate the Hi Limit Controls on the rear of the unit Rem...

Страница 7: ...carbon buildup on the conveyor belt 5 See Figures 6 9 Inspect the rear belts for any tears discoloration or damage to the Belt Wrap snaps Replace any damaged Belt Wrap as needed With proper maintenance the Crown and Main Belt Wraps can six months or longer 6 If the rear belt is in good condi tion spray a clean sanitizer soaked towel with Sink Detergent solution Wipe the rear belt clean Rinse the r...

Страница 8: ... 1011443 Rev C 08 17 Figure 7 Example of Damaged Belt BELT IS TORN AND FOLDED REPLACE BELT BELT IS MISSING SNAPS AND IS DAMAGED REPLACE BELT Figure 8 Example of Damaged Belt Figure 9 Example of Damaged Belt ...

Страница 9: ...bris from both side compartments inside of the toaster and underneath the rollers Install Belt Wraps 1 If you are installing the existing belt wraps inspect the belts Replace belt wraps if worn or damaged If the belt wraps are in good condi tion put them back on the toaster 2 For new or existing belts wipe both sides of the belts with a clean sanitizer soaked towel Allow to air dry 3 Slide the bel...

Страница 10: ...on bristled brush Be careful not to disrupt any of the electrical wiring 5 Slowly close the control housing cover Reconnect with the screws 6 Remove the screws from the bot tom plate on the rear of the unit and slowly lower the cover 7 Remove any debris or dust from the cooling fan with a small brush Wipe away any debris with a clean dry towel Inspect the electrical com partment for crumbs and deb...

Страница 11: ...chain or sprockets damaged Failed Motor Failed Control Board Control Display flashes SpEd Mechanical bind in one or both conveyors Enter user mode to check motor speed Check both conveyors for mechanical binds Replace necessary parts Contact your mainte nance person or Antunes Technical Service for service Worn or damaged Ball Bearings Conveyor chains loose or damaged Drive chain or sprockets dama...

Страница 12: ... Electrician for service Faulty Transformer Replace Transformer Conveyors not turning Belt is damaged Replace Belts Motor Drive Chain is detached from sprockets Reinstall the Drive Chain Failed Drive Motor Contact your maintenance person or Antunes Technical Service for service Belts are ripped or torn Rollers or Heater Cover Plates are dirty and need to be cleaned Clean Rollers and Heater Cover P...

Страница 13: ...38 16 18 43 45 69 7 69 28 15 29 55 10 19 68 50 72 20 78 34 36 68 68 47 21 70 68 9 68 30 14 45 42 8 69 51 69 28 13 29 51 2 56 82 82 24 25 2X 2X 3X 70 70 2X 70 4X 1 60 60 3X 3X 2X 2X 3X 3X 2X 39 40 23 42 50 35 60 60 REPLACEMENT PARTS ...

Страница 14: ... 4 85 68 66 83 62 12 76 44 58 54 71 81 33 69 52 45 41 52 82 49 5 69 73 68 84 66 65 64 68 37 31 68 3 67 80 62 70 26 77 74 53 63 74 75 17 8X 2X 2X 2X 2X 2X 2X 2X 2X 2X 60 8X 3X 2X 61 4X 2X 2X 2X 47 4X 2X 5X 5X 6X 4X 2X 59 40 39 AIR FLOW 6 ...

Страница 15: ...PLATE TENSIONER LH 1 44 0600143 SPRING COMPRESSION 1 45 0600158 SPRING ROLLER TENSIONER 4 46 0701026 WIRE SET 1 47 0800473 ROD HSG SPACER 14 375 LG 4 48 1001213 LABEL SHOCK HAZARD 1 49 1001664 LABEL CONTROL 1 50 2100212 HANDLE POCKET PULL SNAP IN 2 51 2100253 KNOB 1 4 SHAFT PUSH ON 2 52 2100333 TEFLON STRIP 2 53 2110197 CLIP STEEL CABLE 2 54 2120221 SHAFT SPACER 2 55 2120233 SPACER 252ID X 5OD X 9...

Страница 16: ... does not cover water contamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service agency 2 Antunes reserves the right to make changes ...

Отзывы: