Chapter 5: SERVICE - INFORMATION
Operating manual DC6AT
Page 23 of 28
0
2
4
6
8
10
12
14
16
18
0
100
200
300
400
500
overcurrent in %
t
in
s
e
c
P5=50
P5=100
P5=500
5.2.8 Motor constant
Nominal voltage of the motor
5.2.9 Ohmic resistance of the motor
Necessary needed for IxR compensation. This value represents all losses in the motor, not
just the winding resistance. Unfortunately this value is dependent on temperature, speed,
and/or load.
5.2.10 Offset set speed / set speed multiplier
Set speed characteristic curve can be changed.
set speed
Offset
multiplier
5.2.11 Threshold over temperature / overvoltage
Safety limits of the device can only be changed by ANTEK.
5.2.12 Acceleration ramp
Slope of the acceleration ramp
5.2.13 Response after fault
Defines the behaviour after a fault (under/overvoltage, over temperature). A fault can be re-
set either automatically after correction or externally through a reset flank (dependent on the
setting of Parameter 12 – can only be changed by ANTEK).